Installation Instructions

AUXILIARY OUTPUTS 1-2 PARTITION SELECTION
Segments 1 2
Partition 1 1 1
Partition 2 2 2
Partition 3 3 3
45
Partition 4 4 4
AUXILIARY OUTPUTS 1-2 SPECIAL TIMING
Segments 1 2
Auxiliary output timed in minutes 1 1
Auxiliary output to latch 2
2
Auxiliary output to stop timing when user code is entered
3
3
Auxiliary output to activate only between closing and opening
time
4 4
Auxiliary output to activate only between opening and closing
time
5 5
Invert auxiliary output (0 volts going to 12 volts when activated) 6
6
Reserved 7 7
46
Reserved 8 8
AUXILIARY OUTPUT 1, EVENT & TIME (relays 1)
Segment 1
Program the event number for output 1
7=Each siren activation
47
Segment 2
Program the timing for output 1
0 sec.=follow event
AUXILIARY OUTPUT 2, EVENT & TIME (relays 2)
Segment 1
Program the event number for output 2
7=Each siren activation
48
Segment 2
Program the timing for output 1
0 sec.=follow event
AUTOTEST CONTROL
Segment 1
Program a “1” if the interval is hours, or a “0” for
days. Add a “2” to suppress the daily test or a “3”
to suppress the hourly test
0
Segment 2
Program the autotest interval from 1-255 days or
hours
1
Segment 3
Program the autotest report in 24 hour time
format
2
51
Segment 4
Program the autotest report time, minutes after
the hour
0
OPENING TIME / AUTO DISARM TIME
Segment 1
Program the hour of the opening time
8
52
Segment 2
Program the minutes after the hour of the opening time
0
CLOSING TIME / AUTO ARMING TIME
Segment 1
Program the hour of the closing time / auto arming time
20
53
Segment 2
Program the minutes after hour of closing / auto arming
time
0
DAYS OF THE WEEK WHEN “ARM ONLY AFTER CLOSE” WILL ARM/DISARM IN PARTITIONS 1-4
Segments 1 2 3 4
Sunday 1 1 1 1
Monday 2 2 2 2
Tuesday 3 3 3 3
Wednesday 4 4 4 4
Thursday 5 5 5 5
54
Friday 6 6 6 6