Term Definition
keyfob function 2 (see below).
Option 3 A menu option used for configuring a sensor. For actual setting description, see
the particular sensor manual.
Output Latched A menu option that specifies the way the output is timed. If set to Yes, the
output will latch until a code is entered. When set to No, the output is timed
according to Time setting.
Note: Do not set up this option for system status events (such as "Ready to
Arm", "Not Ready to Arm", "Armed", "Disarmed") because once the output is
triggered it will not reset to reflect current status unless the user code is
entered.
Outputs A menu entry that groups programmable options for IO modules.
Partitions A menu entry that lists the partitions assigned to the selected keyfob. The
selected keyfob can trigger an event on these partitions.
A zone may reside in any combination of partitions. A zone that resides in more
than one partition becomes a common zone and is reported to its lowest
partition number. A common zone is armed only when all the partitions that it
belongs to are armed. It is disarmed the moment one of the partitions it
belongs to is disarmed.
Partitions Selects the partition(s) that will trigger the output when the event occurs in
these partition(s).
Receiver Features A menu entry that groups programmable options for RF receivers.
Reset Settings A menu option that defaults the selected receiver to factory defaults.
RF Keypads
A menu entry that displays the RSSI value for the selected wireless keypad.
RF Receiver 32 A menu entry that groups all options for the selected RF receiver. The
integrated NX-10 RF receiver has ID 32.
RF Sensors A menu entry that displays the RSSI value for the selected wireless zone.
RF Sirens/IO A menu entry that displays the RSSI value for the selected wireless siren or IO
module.
RSSI RF Device A menu entry that groups entries related to measuring RF signal strengths.
Sequential Programming A menu option that allows a group of RF sensors to be enrolled in sequence.
Once the first sensor (Start Learning sensor) is configured, the detectors are
learned-in in sequence. The value of ‘Start Learning’ is increased automatically.
This option allows easier programming.
Short Window A menu option that specifies the short supervision window for RF devices. RF
devices on 868 MHz typically report every 15 minutes. Depending on the
country regulations, this timer must be set to specific values.
Sirens/IO Features A menu entry that groups troubleshooting options for IO modules.