Installation Instructions

NX-10 Installers manual
55
silent alarm that sends a special report to the central station. To program codes, select Installer
Menu>Control Panel>Codes.
Note: For EN/INCERT compliance, system access ID needs to be in 6 digit format.
Setting up the installer code
An installer code may have associated arming options and access rights. To set the authority and
access rights, you must enable the advanced menu. The following example assigns partitions 1 and 2
to a new installer code that can be used only to arm the system.
1. Ensure the advanced menu is enabled.
2. Navigate with the ½¾ keys to Control Panel>Codes>Installer Code>Code and press
OK.
3. Enter the new code and press OK.
4. Enter the new code and press OK.
5. The keypad beeps once to confirm the change and returns to Code.
6. Scroll to Authority>Arm Only>Yes and press OK.
7. The keypad beeps once to confirm the change and returns to Arm Only.
8. Navigate with the ½¾ keys to Partitions and press OK.
9. Press the corresponding numerical key to include partitions 1 and 2 and to exclude all
other partitions and press OK.
10. The keypad beeps once to confirm the change and returns to Partitions.