Product Guide

PRELIMINARY
18 19
ADDITIONAL ACCESSORIES AVAILABLE
For example, drain kits, adapter, exterior air deflector kits and filters.
Visit Zoneline.com for full listing.
POWER CONNECTION KITS ARE REQUIRED
ON ALL ZONELINE CHASSIS.
(See chart below)
The correct kit for the installation is determined by the voltage and amperage of the electrical circuit and the means of
connecting the unit to the building wiring. If the unit is to be plugged into a receptacle, a line cord kit would be used; if
the unit is to be permanently connected, a permanent connection kit would be used. Cord set units of 265 volts must be
installed in compliance with National Electrical Code.
®
POWER CONNECTION KITS
Required on all models. See specification information below
for heater kWh and branch circuit ampacity.
7,000/9,000 BTUH
230/208 VOLT LINE CORD CONNECTED UNITS
LCDI Power
Connection Kit RAK315P RAK320P RAK330P
Heater kWh 2.4/1.99 3.42/2.83 4.83/3.98
Watts 2,401/1,989 3,418/2,825 4,827/3,984*
BTU 8,187/6,782 11,655/9,633 16,460/13,585
Amps 10.4/9.6 14.9/13.6 21.0/19.2
Min. circuit amps 15 20 30
Recommended
protective device
15 amp time-
delay fuse or
breaker
20 amp time-
delay fuse or
breaker
30 amp time-
delay fuse or
breaker
7,000/9,000 BTUH
265 VOLT PERMANENT CONNECTED UNITS** (CORD SET)
RAK515P RAK520P RAK530P
2.4 3.4 4.8
2,400 3,400 4,800
8,150 11,550 16,350
9.6 13.3 18.6
15 20 30
15 amp time-delay
fuse or breaker
20 amp time-delay
fuse or breaker
30 amp time-delay
fuse or breaker
7,000/9,000 BTUH
265 VOLT DIRECT CONNECTION KIT†
RAK515D RAK520D RAK530D
2.4 3.4 4.8
2,400 3,400 4,800*
8,150 11,550 16,350
9.6 13.3 18.6
15 20 30
15 amp time-delay
fuse or breaker
20 amp time-delay
fuse or breaker
30 amp time-delay
fuse or breaker
7,000/9,000 BTUH
230/208 VOLT DIRECT CONNECTION KIT†
RAK315D RAK320D RAK330D
Heater kWh 2.4/1.99 3.42/2.83 4.83/3.98
Watts 2,401/1,989 3,418/2,825 4,827/3,984*
BTU 8,187/6,782 11,655/9,633 16,460/13,585
Amps 10.4/9.6 14.9/13.6 21.0/19.2
Min. circuit amps 15 20 30
Recommended
protective device
15 amp time-
delay fuse or
breaker
20 amp time-
delay fuse or
breaker
30 amp time-
delay fuse or
breaker
*Wattage less when in low fan.
**To be used with sub-base.
†To be used with sub-base or connection to building wiring.
Specifications subject to change.
Wall case and exterior grille are also required for new construction.
Specs may vary for 12,000/9,000 BTUh models.
RAK315P/320P/330P
230/208 volt line cord connection kit
Also available with short power cords
RAK315D/320D/330D
230/208 volt universal power supply kit
RAK515D/520D/530D
265 volt universal power supply kit
WALL CASE OPTIONS
RAB71B, RAB77B
Extended sleeves available in 16" and
24" depths
THERMOSTATS
Digital – RAK148D2 , RAK164D2
Programmable –
RAK148P2, RAK164P2
STANDARD SUB-BASE WITH
POWER CORD INCLUDED
RAK204D15PA
RAK204D20PA
RAK204D30PA
ACCESSORIES
RETROFIT KITS
RAK40 Deflector kit
GRILLE OPTIONS
Architectural rear grille
Extruded aluminum –
RAG67
Stamped aluminum – RAG60
High-impact polymer grille
Beige – RAG61
Maple – RAG62
Bittersweet – RAG63
CHASSIS
WALL CASE
ROOM
FRONT
GRILLE
CROSS-FLOW
BLOWER
A look inside: