Installation Instructions
ELECTRICAL SUBBASE
CONNECTION
Power cords may include an arc fault interruption
or a leakage current detection interruption device.
A test and reset button is provided on the plug case
or the inline case. The device should be tested on
a periodic basis by first pressing the TEST button
and then the RESET button. If the TEST button does
not trip or if the RESET button will not stay engaged,
discontinue use of the Zoneline and contact a
qualified service technician.
Depending on application, a power supply kit with LCDI
must be used to supply power to the Zoneline unit. The
appropriate kit is determined by the voltage, the means of
electrical connection and the amperage of the branch
circuit.
Connections of 208 or 230-volt circuits may be with a
power supply kit or a junction box kit.
All wiring, including installation of the receptacle,
must be in accordance with the NEC and local codes,
ordinances and regulations. Codes require the use of
an arc fault or leakage current detection device on the
power cord except direct connect. Be sure to select the
correct cord for your installation.
Branch Circuit and Proper GE Power Cord
Unit Amperage Rating with LCDI Device
15 RAK315P
20 RAK320P
30 RAK330P*
230/208 VOLT ELECTRICAL CONNECTION OPTIONS
POWER
CORD CONNECTION
DIRECT CONNECTION
Order the following Kit for 230/208-volt direct
connection as required:
Review installation instructions provided with power
cord or direct connect kits for detailed assembly
instructions.
If using a sub-base connection, the RAK4002C Junction
Box is also necessary for a complete installation.
Branch Circuit and Proper GE
Unit Amperage Rating Subbase Kit
15 RAK204D15PA
20 RAK204D20PA
30 RAK204D30PA
Tandem
15 Amp
230/208 volt receptacle configuration
Perpendicular
20 Amp
Large Tandem
30 Amp
Branch Circuit and
Unit Amperage Rating
Power
Supply Kit
15 RAK315D
20 RAK320D
30 RAK330D
Power supply kit
(Appearance may vary)
230/208-volt models may be installed using one
of the following electrical subbases:
Electrical subbases provide an enclosure for direct
connection or enclosed receptacles. The subbase kit
includes the power cord.
The instructions provided with the selected subbase kit
must be carefully followed. It is the responsibility of the
installer to ensure the connection of components is done
in accordance with these instructions and all electrical
codes.
If using a sub-base connection, the RAK4002C Junction
Box is also necessary for a complete installation.
16