Use and Care Manual

Examples
Timer set to ON/OFF REMOTE ON – OUTPUT ON; REMOTE OFF - OUTPUT OFF
Timer set to DUSK-DAWN
When DUSK = 6:00 PM and DAWN = 5:00 AM
If at 4 :00 PM REMOTE activated to ON --> OUTPUT ON and stay ON until 5:00 AM.
Next day ON at DUSK , OFF at – DAWN
If at 10 :00 PM REMOTE activated to OFF --> OUTPUT OFF = 10:00 PM, and stays OFF
until DAWN next day. Next day ON at DUSK , OFF at DAWN
If TIMER setting is 2 HOURS (or 4,6 & 8 HOURS)
DAY OR NIGHT TIME
REMOTE ON --> OUTPUT ON 2 HOURS (4,6.8 HOURS) Then OFF
When DUSK --> OUTPUT ON 2 HOURS (4,6,8 HOURS) Then OFF
If DUSK is at 6:00 PM
(1) If at 5 :00 PM REMOTE set ON , then OUTPUT ON immediately until 8:00 PM (as
time count restarted at dusk time).
(2) TIMER ON = 6:00 PM, TIMER OFF = 8:00 PM. If at 1 :00 PM REMOTE set ON ,
then OUTPUT turns ON until 3:00 PM.
(3) TIMER ON = 6:00 PM. If at 7:00 PM REMOTE set ON OUTPUT ON until 9:00 PM(as
time count restarted at time remote activates to ON).
(4) TIMER ON = 6:00 PM. If at 7:00 PM REMOTE set OFF, then OUTPUT turns OFF
immediately until next day.
ELECTRICAL RATINGS
15AMPS General Purpose 1000W Tungsten 120Vac,60Hz
Note: Tungsten rating relates to the total wattage of light bulbs used.
Resistive is the rating for appliance.
15143
Manual Version 1
05/25/10
www.jascoproducts.com