SDS

IDH number: 2795576
Product name: GE ALL PURPOSE SILICONE W&D PROJECTS
Page 3 of 5
Vapor pressure:
< 10 mm hg (20 °C (68°F))
Boiling point/range:
Not available.
Melting point/ range:
Not available.
Specific gravity:
1.01 at 20 °C (68°F)
Vapor density:
Heavier than air.
Flash point:
> 93 °C (> 199.4 °F)
Flammable/Explosive limits - lower:
4 %
Flammable/Explosive limits - upper:
19.9 %
Autoignition temperature:
Not available.
Flammability:
Not applicable
Evaporation rate:
Not available.
Solubility in water:
Not determined
Partition coefficient (n-octanol/water):
Not available.
VOC content:
3.0 %; 30 g/l
Viscosity:
Not available.
Decomposition temperature:
Not available.
10. STABILITY AND REACTIVITY
Stability:
Stable under normal conditions of storage and use.
Hazardous reactions:
Will not occur.
Hazardous decomposition
products:
Oxides of carbon. Oxides of silicon. Formaldehyde.
Incompatible materials:
Oxidizing agents.
Reactivity:
Not available.
Conditions to avoid:
Prolonged heating at temperatures above 150 °C. Exposure to moisture.
11. TOXICOLOGICAL INFORMATION
Relevant routes of exposure:
Skin, Inhalation, Eyes, Ingestion
Potential Health Effects/Symptoms
Inhalation:
When heated to temperatures exceeding 300° F (150° C) in the presence of air, silicones may
form formaldehyde vapors. Formaldehyde is a potential cancer hazard and a known skin and
respiratory sensitizer. Vapors irritate the eyes, nose and throat. Safe handling conditions may
be maintained by keeping formaldehyde vapor concentrations below the OSHA permissible
limit. May cause respiratory tract irritation.
Skin contact:
Causes skin irritation.
Eye contact:
Causes serious eye irritation.
Ingestion:
May cause gastrointestinal tract irritation if swallowed.
Hazardous Component(s)
LD50s and LC50s
Immediate and Delayed Health Effects
Silicon dioxide
Oral LD50 (Rat) = > 22,500 mg/kg
Oral LD50 (Mouse) = > 15,000 mg/kg
Inhalation LC50 (Rat, 4 h) = > 2.08 mg/l
Inhalation LC50 (Rat, 4 h) = > 0.69 mg/l
Nuisance dust
Hazardous Component(s)
NTP Carcinogen
IARC Carcinogen
OSHA Carcinogen
(Specifically Regulated)
Silicon dioxide
No
No
No
12. ECOLOGICAL INFORMATION
Ecological information:
Not available.