Instruction Manual

Observe Important Wiring Information
Important: This switch is rated for and intended to
only be used with copper wire.
Models 45609 and 45612 ONLY: The home’s electrical
wires may be attached to the screw terminals or
inserted into the holes in the back of the switch
enclosure and clamped in place by tightening the
screw terminals. Always follow the recommended wire
strip lengths when making wiring connections.
Wire strip length:
For attachment to screw terminals: Strip insulation
5/8(max 14 AWG wire).
For attachment using the enclosure’s holes: Strip
insulation 5/8” (max 14 AWG wire).
OPERATION
When installed with the 45607 or 45612 dimmer:
Press and release the top of the 45610’s rocker to turn the
connected lighting ON and return the brightness level to
its previous setting.
Press and hold the top of the 45610’s rocker to turn
the connected lighting ON and set the brightness level.
Release when the desired level is attained.
Press the bottom of the 45610’s rocker to turn the
connected lighting OFF.
Press and hold the bottom of the 45610’s rocker to lower