User manual
– 31 –
High Voltage Transformer
1. Remove the control panel (see procedure).
GEA01015
High Voltage
Transformer
Transformer
High Voltage
Transformer
2. Remove the low voltage transformers (see
procedure).
3. Disconnect the high voltage transformer
wiring.
GEA00987
ScrewsScrews
4. Remove the right cooktop filter.
5. Access and remove 4 screws securing the
high voltage transformer.
6. Remove the transformer.
Magnetron
1. Remove the control panel (see procedure).
2. Remove the low voltage transformers (see
procedure).
3. Remove the high voltage transformer (see
procedure).
4. Disconnect the wiring from the magnetron and
the magnetron TCO.
GEA00997
ScrewsScrews
ScrewsScrews
MagnetronMagnetron
Magnetron
TCO
Magnetron
TCO
5. Remove 4 screws and the magnetron.
Damper Assembly
1. Remove the control panel (see procedure).
2. Disconnect the damper motor wire leads.
3. Remove 3 screws and lift the damper motor
assembly straight up to disengage the damper
door and remove.
Note: Be certain linkage to damper outlet door is
connected when reassembling.
GEA01130
Damper Outlet
Damper Outlet
Door Linka
Door Linka
ge
Damper Outlet
Door Linkage
Damper Door
Damper Door
Sensing Switc
Sensing Switc
h
Damper Door
Sensing Switch
Mounting
Mounting
Screws (3)
ws (3)
Mounting
Screws (3)
Note: Photo shows casing removed for
clarity.