BEFORE YOU BEGIN
Read these instructions completely and
ca refu IIg.
IMPORTANT - savethese instructions for local
inspector's use.
IMPORTANT - Observeallgoverningcodes
and ordinances.
Note to Installer - Besure to leave these instructions
with the Consumer.
Note to Consumer - Keep these instructions for future
reference.
Skill level - A licensed, certified (to handle refrigerant-
R410A,recovery, etc.)technician and a qualified
electrician ore required for installation of this split
air conditioning system.
Completion time - Approximately 2V2hours
Two people are required to install this unit due to
the weight of the product.
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not
covered under the Warranty.
For personal safety, this system must be properly
grounded.
Protective devices (fuses or circuit breakers)
acceptable for installation ore specified on the
nameplate of each unit.
Servicing and installation of the refrigerant system
must be performed only by a licensed, HVAC-certified
technician.
Make sure to avoid wiring or plumbing inside the wall
when installing.
Forany service which requires entry into the refrigerant
sealed system, Federal regulations require the work be
performed by o technician having o Class IIor Universal
certification.
ELECTRICAL REQUIREMENTS
Becertain all wiring complies with local building codes and
NECand that the supply voltage for this system iscorrect.
The system supply voltage is connected to the outdoor
unit only.
Checkthe rating nameplate on the side panel of outdoor
unit for requiredcircuit protection rating and required supply
voltage.
UseUL-opprovedelectrical branch circuit disconnect
for providing supply voltage to split system indoor and
outdoor units. Locate disconnect within sight and readily
accessibleper NECand local codes.
Allwiring should be rated appropriate for the current value
listed on the rating plate.
Becertain there isan uninterrupted, unbroken electrical
ground connection.
Wiring should be encased in liquid-tight tubing with
connections sealed with liquid-tight connectors.
-&CAUTION:
Do not use on extension cord with this system.
Aluminum building wiring mag present special
problems-consult a qualified electrician.
When the unit is in the STOPposition, there is still
voltage to the electrical controls.
Disconnect the power to the system before
servicing bg removing the branch circuit fuses
or turning the circuit breakers off at the panel.
DO NOT use equipment certified for R22 refrigerant
only.