Installation Guide
4
About the controls on the air conditioner.
Features and appearance will vary.
Lights next to the touch pads on the air conditioner control panel indicate the selected settings.
Fan Fan
 Delay  1–24hr
 Delay  timer 
Decrease
Mode select
Fan speed 
Decrease
Temperature 
set Increase 
and Decrease
 Delay 
timer 
Increase 
 Auto  Fan   
on
Fan speed  
Increase
 Unit  power 
on/off
Air Conditioner Controls
Controls
Power Pad
Turns air conditioner on and off. When 
turned on, the display will show the room 
temperature.
Display
Shows the room temperature or time remaining 
on the Delay timer. Shows the Set temperature 
while setting the temperature in Cool or Energy 
Saver modes. The Set light will turn on while 
setting.
Temp Increase Ÿ /Decrease ź Pads
Use to set temperature when in Cool or 
Energy Saver mode. The Set light will turn on 
while setting.
Delay Timer IncreaseŸ (+) /Decrease 
ź(–) Pads
Each touch of the Increase Ÿ / Decrease ź 
pads on the unit or the Increase + / Decrease 
– pads on the remote control will set the delay 
time when using the Delay 1–24hr timer. The 
Set light will turn on while setting.
Fan Speed Pads
Use to set the fan speed to Low, Med, High  
or Auto on the unit. NOTE: On the remote 
control, use the fan speed Increase + / 
Decrease – pads to set the fan speeds to Low, 
Med or High. Use the Auto pad to turn Auto 
fan on.
Mode Pad
Use to set the air conditioner to Cool, Energy 
Saver or Fan Only mode.
Delay Pads/Delay 1-24hr Pad
'HOD\21³When the air conditioner is off, it can 
be set to automatically come on in 1 to 24 hours 
at its previous mode and fan settings. 
'HOD\2))³When the air conditioner is on,  
it can be set to automatically turn off in 1 to  
24 hours. 
How to set:
Press the Delay 1–24hr pad on the unit or the 
Delay pad on the remote control. Each touch 
of the Increase Ÿ / Decreaseźpads on the 
unit or the Increase 
+ / Decrease – pads on 
the remote control will set the timer in 1-hour 
intervals. The Set light will turn on while setting.
To review the remaining time on the Delay 
1–24hr timer, press the Delay 1–24hr pad on 
the unit or the Delay pad on the remote control. 
Use the Increase Ÿ / Decrease ź pads on the 
unit or the Increase 
+ / Decrease – pads on the 
remote control to set a new time if desired.
To cancel the timer, press the Delay 1–24hr pad 
until the light on the Delay 1–24hr pad goes off.
Reset Filter
LED will turn on when fan has accumulated 250 
hours of run time as a reminder to clean filter. 
Press Reset Filter to turn off the LED and reset 
the accumulated run time.
Note: The default temperature reading on the display is degree Fahrenheit ( °F). To change the display to 
degree Celcius (°C), press the Temp Increase Ÿ and Temp Decrease ź buttons together and hold for 3 
seconds. Repeat the process to change back to degree Fahrenheit (°F)
NOTE: The display always shows the room temperature except 
when setting the Set temperature or the Delay timer.
Power
On/Off
Fan Mode
Auto
Reset
Filter
High
Med
Low
Cool
Fan Only
Energy Saver
Delay
1-24 Hrs
Set
+
-
8
Light indicates the 
delay timer is set.
Light indicates the unit is in the 
temperature or delay time Set mode.
Remote Control