Operating instructions

21
Level I Programming
The AvantaPure control can be quickly programmed by
following the sequential procedure. Level I program
parameters are those that can be accessed by pressing
the UP or DOWN buttons.
Model Number: Select a model from the table based
on the application. Review Table 1 and determine
your model number before you start.
Time of Day: Includes PM indicator. Can be set to
display as a 24-hour clock. See Level ll programming
Day of Week: Set to actual day of the week.
Time of Regeneration: Fully adjustable. Default is
2:00 AM.
Note:
When the control is set up for a twelve-hour clock
a PM indicator will illuminate when the displayed time is in
the PM hours. There is no AM indicator.
Table 1
This table is for reference only. Your model number should
be set by an AvantaPure Water Treatment Professional
based on your specific application requirements.
Model
Number
Tank
Diameter
Resin Cu. Ft.
Total Salt
Dosage
lbs
Total
Capacity
Kilograins
Injector
Type
47
10 x 40
1.00 Ft
3
2.5 10,000 5 Bump
48
10 x 40
1.00 Ft
3
3.5 12,000 5 Bump
49
10 x 40
1.00 Ft
3
8.5 20,000 5 Bump
50
10 x 40
1.00 Ft
3
13 22,000 5 Bump
51
10 x 44
1.25 Ft
3
313,0005 Bump
52
10 x 44
1.25 Ft
3
11 25,000 5 Bump
53
10 x 44
1.25 Ft
3
16 28,000 5 Bump
54
10 x 54
1.50 Ft
3
4.0 16,000 5 Bump
55
10 x 54
1.50 Ft
3
5.0 18,000 5 Bump
56
10 x 54
1.50 Ft
3
12.5 30,000 5 Bump
57
10 x 54
1.50 Ft
3
19 33,000 5 Bump