Spec Sheet

AZ95E12DAC
GE Zoneline
®
Cool/Electric Resistance Heat
Vertical Air Conditioner 230/208 Volt
Specification Created 12/20
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
31-7/8
23-5/8
24-1/8
POWER CONNECTION REQUIREMENTS (RESISTANCE HEAT)
230/208 VOLT 9,000/12,000 BTUh 18,000 BTUh
POWER
CONNECTION KIT
RAK315D RAK320D RAK330D RAK320D RAK330D
Heater Watts 2450/2004 3450/2822 5000/4089 3450/2822 5000/4089
MCA 15 20 30 20 30
Recommend
Protective Device
(MOCP)
15 amp
time-delay
fuse or
breaker
20 amp
time-delay
fuse or
breaker
30 amp
time-delay
fuse or
breaker
20 amp
time-delay
fuse or
breaker
30 amp
time-delay
fuse or
breaker
*There is no 15 amp breaker option available for 18,000 BTUh models due to compliance with UL standard 60335-2-40
MINIMUM CLEARANCES:
FRONT-ACCESS CLOSETS
-Allow 3" in front of unit, Allow 3" on each side of unit.
SIDE-ACCESS CLOSETS
- Allow 5" in front of unit, Allow 3" on each side of unit.
REQUIRED COMPONENTS FOR INSTALLATION
- Drain Platform (RAVDPLAT)
- Plenum or Transition Plenum
- Exterior Grille
- Return Air Grille/ Access Panel
- Remote Thermostat
- Power Connection Kit
For answers to your Monogram, GE Café
, GE Profile
or GE Appliances
product questions, visit our website at geappliances.com or call
GE Answer Center
®
Service, 800.626.2000.
PERFORMANCE DATA AT 230 VOLT
- Cooling Capacity – 11,500 BTUh
- EER - 12.1

Summary of content (2 pages)