Dimensions Guide

C2Y366SELSS
GE Café
Series 36" Dual Fuel Professional Range with 6 Burners (Natural Gas)
For answers to your GE Appliances product questions, visit our website
at geappliances.com or call GE Answer Center
®
Service, 800.626.2000.
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
Specification Revised 10/17
All GE Appliances ranges are equipped
with an Anti-Tip device. The installation
of this device is an important, required
step in the installation of the range.
Listed by
Underwriters
Laboratories
NOTE: Professional ranges offer a number of choices
in size and cooktop configurations. All Professional
Ranges are factory set for natural gas.
NOTE: Conversion kits are included with the range.
High Altitude kit, WB28K10553 for operation above
3,000 feet (for Natural and LP gas models), is also
available. The kits must be installed by a qualified
service technician at additional cost.
INSTALLATION INFORMATION : Before
installing, consult installation instructions packed
with product or online at geappliances.com for
current dimensional data.
A suitable 36" or wider vent hood is required
for installation over ranges with a grill and
recommended for all other ranges.
ADVANCE PLANNING: Refer to dimensional
drawings for appropriate placement and necessary
clearances when planning the installation.
- Working areas adjacent to the range should have
18" minimum clearance between countertop and
cabinet bottom.
- Clearance between range and side wall or
combustible material must be at least 12" on
each side.
- Installation must conform with local codes.
In the absence of local codes, the range must
comply with the National Fuel Gas Code,
ANSI Z223.1-1990.
35 7/8" width
28 1/4"
35 1/4"
to
36 3/4"
height
3 1/4"
to 4 3/4"
Toekick/leg
height
Depth
to front
of door
1" Countertop to
Cooking Surface
C2Y366SELSS
WARNING: Installations without a hood require
48" minimum to combustibles. A custom hood
installation with exposed horizontal combustible
surfaces must have an Auto-On feature. Refer to
hood installation instructions for specific hood
clearances.
The surface of the entire back wall above the range
and below the hood must be covered with a non-
combustible material such as metal, ceramic tile,
brick, marble or other stone.
ADDITIONAL CLEARANCES:
Allow 12" minimum clearance to an adjacent wall
on each side.
Working areas adjacent to the rangetop should have
18" minimum clearance between countertop and
the bottom of the wall cabinet.
Non-Combustible
Material
13"
max.
18"
min.
36" min.
48" minimum
to combustibles
12" minimum
each side
12" minimum
to adjacent wall