Installation Guide

CONVERTING TO PROPANE GAS (OR CONVERTING BACK
TO NATURAL GAS FROM PROPANE)
This cooktop leaves the factory set for use with natural gas. If you want to convert to
propane gas, the conversion must be performed by a qualified propane gas installer.
7KHFRQYHUVLRQRULILFHVDQGLQVWUXFWLRQVFDQEHIRXQGDWWDFKHGWRWKHUHJXODWRU
.HHSWKHVHLQVWUXFWLRQVDQGDOORULILFHVLQFDVH\RXZDQWWRFRQYHUWEDFNWRQDWXUDOJDV
RECOMMENDED GAS
SUPPLY LOCATION FROM
BACKWALL
OVERALL COOKTOP DIMENSIONS
CUTOUT DIMENSIONS OF COUNTERTOP
7RHQVXUHDFFXUDF\LWLVEHVWWRPDNHDWHPSODWHZKHQFXWWLQJWKHRSHQLQJLQWKHFRXQWHU
DIMENSIONS AND
CLEARANCES
3URYLGHDGHTXDWHFOHDUDQFHVEHWZHHQWKH
FRRNWRSDQGDGMDFHQWFRPEXVWLEOHVXUIDFHV
7KHVHGLPHQVLRQVPXVWEHPHWIRUVDIHXVHRI
\RXUFRRNWRS
$OORZ´FPPLQLPXPFOHDUDQFH
EHWZHHQEXUQHUVDQGERWWRPRIXQSURWHFWHG
ZRRGRUPHWDOFDELQHWRUDOORZD´
FPPLQLPXPZKHQERWWRPRIZRRGRUPHWDO
FDELQHWLVSURWHFWHGE\QROHVVWKDQ´
PPWKLFNIODPHUHWDUGDQWPLOOERDUGFRYHUHG
ZLWKQROHVVWKDQ1R06*VKHHWPHWDO
´>PP@WKLFN´PPWKLFN
VWDLQOHVVVWHHO´PPDOXPLQXPRU
´PPFRSSHU
,QVWDOODWLRQRIDOLVWHGPLFURZDYHRYHQRU
FRRNLQJDSSOLDQFHRYHUWKHFRRNWRSVKDOO
FRQIRUPWRWKHLQVWDOODWLRQLQVWUXFWLRQVSDFNHG
ZLWKWKDWDSSOLDQFH
%XLOWLQRYHQLQVWDOODWLRQVKDOOFRQIRUPWRWKH
LQVWDOODWLRQLQVWUXFWLRQSDFNHGZLWKWKHEXLOWLQ
RYHQ
MAINTAIN THE FOLLOWING MINIMUM CLEARANCE
DIMENSIONS
FOR AMERICANS WITH
DISABILITIES ACT (ADA)
FORWARD APPROACH
INSTALLATION ONLY
NOTE: 7KHHQFORVXUHPXVWEHPDGHRIZRRG
PDWHULDO$OVRDQDFFHVVSDQHOLVUHTXLUHGIRU
WKHHOHFWULFDORXWOHWSUHVVXUHUHJXODWRUVKXWRII
YDOYHKROGGRZQEUDFNHWVDQGVHUYLFH
´0LQ)URP%DFNZDOO
Ǝ
)URP
&XWRXW
&HQWHU
/LQH
5HFRPPHQGHG
JDVVXSSO\
ORFDWLRQ
$OORZ´PLQLPXPGHSWK
EHWZHHQWKHFRXQWHUWRS
DQGDQHQFORVXUH
´
NOTE:$OORZ´PLQLPXPYHUWLFDOFOHDUDQFHIURPWKHFRRNWRS
ERWWRPRU´PLQLPXPGHSWKIURPWKHFRXQWHUWRSWRDQ\
FRPEXVWLEOHVXUIDFHVVXFKDVDFDELQHWGUDZHU
)RULVODQGLQVWDOODWLRQPDLQWDLQLQPLQLPXPIURPFXWRXWWRIURQW
DQGEDFNHGJHRIFRXQWHUWRS0DLQWDLQLQPLQLPXPIURPFXWRXWWR
VLGHHGJHVRIFRXQWHUWRS
3 3/4 MIN.
Ǝ0$;'HSWK
RIXQSURWHFWHG
RYHUKHDGFDELQHWV
Ǝ0,1KHLJKW
IURPFRXQWHUWRSWR
QHDUHVWFDELQHWRQ
HLWKHUVLGHRIXQLW
´RU´
FDELQHWEDVH
RUZLGHU
R0,1FOHDUDQFH
IURPFXWRXWWRULJKW
VLGHZDOO
L0,1FOHDUDQFHIURP
FRRNWRSWROHIWVLGHZDOO
C0,1FOHDUDQFH
IURPFXWRXWWRUHDUZDOO
´0,1IURPFXWRXW
WRIURQWRIFRXQWHUWRS
Ǝ0,1FOHDUDQFH
IURPFRXQWHUWRS
WRXQSURWHFWHG
RYHUKHDGVXUIDFH
ALL HORIZONTAL
CLEARANCES MUST
BE MAINTAINED FOR A
MINIMUM OF 18” ABOVE
THE COOKING SURFACE.
CLR
JGP3030, JGP3530, JGP3036 ´ ´ ´
JGP5030, PGP7030, CGP7030,
PGP9030, CGP9530
´ ´ ´
JGP5036, PGP7036, CGP7036,
PGP9036, CGP9536
´ ´ ´
Ǝ
Ǝ
DRAWER
'5$:(5
&RRNWRS
Ǝ
Ǝ
Ǝ
Ǝ
Ǝ
Ǝ
´
OHQJWK
RIFXW
´ZLGWKFXW
&RRNWRS
Ǝ
Ǝ
Ǝ
Ǝ
Ǝ
30” Models 36” Models
Ǝ
´
OHQJWK
RIFXW
´ZLGWKFXW
30” Models 36” Models