Manual

49-80819 17
Installation Instructions
INSTALLATION PREPARATION
3
CONNECT DUCTWORK
Ŷ ,QVWDOOGXFWZRUNPDNLQJFRQQHFWLRQVLQGLUHFWLRQ
of airflow as illustrated.
Ŷ 6HFXUHMRLQWVLQGXFWZRUNZLWKVKHHWPHWDOVFUHZV
Ŷ :UDSDOOGXFWMRLQWVZLWKGXFWWDSHIRUDQDLUWLJKW
seal.
Ŷ 8VHGXFWWDSHWRVHDOWKHIODQJHFRQQHFWLRQ
Reach inside the hood and push the damper up
to be sure it moves freely.
5
INSTALL DUCT COVERS
NOTE: For easier handling, remove cardboard
insert after film is peeled off.
Remove protective film from duct covers. If more
than one duct cover is used, secure each piece
together with screws provided.
Ŷ 3ODFHWKHGXFWFRYHUVRQWRSRIWKHKRRG
Ŷ )URPLQVLGHWKHKRRGVHFXUHWKHGXFWFRYHU
to the top with the small Phillips head screws
supplied with the covers.
4
CONNECT ELECTRICAL
Verify that power is turned off at the source.
WARNING
If house wiring is not 2-wire with
a ground wire, a ground must be provided by the
installer. When house wiring is aluminum, be sure
to use U.L. approved anti-oxidant compound and
aluminum-to-copper connectors.
Ŷ 8VHZLUHQXWVWRFRQQHFWLQFRPLQJJURXQGWR
green, white to white and black to black.
Ŷ 3XVKZLUHVLQWRMXQFWLRQER[DQGUHSODFHFRYHU
Be sure wires are not pinched.
Screw
Duct Tape
Over Seam
and Screw
Air Flow
Duct Tape
Over Transition
White
Ground
Black
Remove
Junction Box
Cover
A.
Insert Power
Conduit Thru
Strain Relief
and Tighten
B.
Use UL Listed
Wire Nuts
C.