Manual

Installation Instructions
MOBILE HOME INSTALLATION
1, Dryer MUST be exhausted outside (outdoing, not
beneath the mobile home) using metal ducting that will
not support combustion. Metal ducting must be 4"
(l 0.l 6 cm) in diamemr with no obstructions. Rigid metal
duct is preferred.
2, If the dryer is exhausmd through the flora; the exhaust
svsmm MUST NOT temfinate beneath the mobile
home. Temfination MUST be secm'elv fi_stened to the
mobile home structm'e.
3. When installing a gas (hyer into a mobile home, a
provision illtlSt be made tin" outside make-up air. This
provision is to be not less than twice the area of the (hwer
exhaust outlet.
4. Gas (h've_5 MUST be fi_stened to the floor using Mobile
Home Installation t4dt Pub. No. 14-D346-33.
5, See the Exhaust System Requirements section fin" other
important venting infiwmation.
6. Installation MUST confimn to cmTent Manufi_cmred
Home Construction & Safety Standard (which is a
Federal Regulation Title 24 CFR--Part 32-80) m;
when such standard is not applicable, with/hnerican
National Standard fin" Mobile Homes, ANSI/NFPA No.
501B. In Canada, the CSA Z240 is applicable.
Correct
Incorrect
Don't
Thedryer is designedunderANSIZ 21.5.1.
ROUGH-IN DIMENSIONS
267/8" _1
(68.3cm)
/
Electricalconnection
29/16" _ ,
(6.6cmT_'_
139/16"
(34.5cm)]
1 ©
-f_ 3/16"(0.48cm)Dia.
33/4" gaspipe
(9.5cm)
REAR VIEW
t
Under
counter
345/8"
(87.9cm)
36"
(g1.5cm)
!
<
3/4"
(1.9cm)
Dooropen
90°
47 1/2"
(120.7cm}
4 3/8"
(11.1cm7""-_!
0pti0na_.,L. '
ventknockout . '-
__ 253/4" __
(65.4cm)
SIDEVIEW
_L
i
t
33/4"
(9.5cm)
SERVICING - Consideration m ust be given to provide
adequate clearances t0r installation and servicing.
15