4
Rejection
=
[(C
avg
) - (C
P
)] x 100
(C
avg
)
=
[(237.5 mg/L) + (8.3 mg/L)] x 100
(237.5)
=
96.5%
Passage
=
(C
P
) x 100
(C
f
)
=
(8.3 mg/L) x 100
(237.5)
=
3.5%
Recovery
=
(Q
P
) x 100
(Q
f
)
=
(18 gpm) x 100
(24gpm)
=
75%