Installation Guide

FIGURE 10, 11 & 12
FIGURE 12
H. Tilt the luminaire and insert it into the mount box
tting. Use 3M 314 waterproof connectors to connect
power cable from luminaire where Black is Line,
White is Neutral and green is ground to SJOW cable wire.
(See Fig.10, 11)
I. Lift and push luminaire up to mount box.
Fasten 2 M4 to secure luminaire with mount box.
(Fig. 11 & Fig. 12)
FIGURE 13
G. From under the structure fasten 4pcs M8 nut lock
washer and washer to x mount box with ceiling
and plate bracket. Torque top and bottom bolts to
25 - 32 ft-lbs (34-43 N-m). (See Fig.9)
FIGURE 9
Recessed Installation
Stud
F. Tighten the screw (4-M4) to assemble junction box
with plate bracket. Torque reference 2.1ft-lbs
(2.9 N-m). (See Fig. 8)
1. Cut a square hole on Ceiling. Additional studs may
be required to xed on ceiling rib.
Hole size: 12”x 12”/ 16” X 16”
2. Mount the light housing and secure to the studs.
The light housing mounting hole are sized for ¼”
diameter screw.
Light Housing