Product Datasheet

Technical Data
GEH5.0-1U-US10 GEH6.0-1U-US10 GEH7.0-1U-US10 GEH7.6-1U-US10 GEH8.6-1U-US10 GEH9.6-1U-US10
Battery Input Data
Battery Type Li-Ion
Nominal battery voltage (V) 300
Battery Voltage Range (V)*
1
80~495
Max. Continuous Charging Current (A) 50
Max. Continuous Discharging Current (A) 50
Max. Charge power (W) 5000 6000 7000 7600 8600 9600
Max. Discharge Power (W) 5000 6000 7000 7600 8600 9600
PV String Input Data
Max. Input Voltage (V)*
2
600
MPPT Operating Voltage Range (V)*
3
80~550
Start-up Voltage (V) 95
Nominal Input Voltage (V) 380
Max. Input Current per MPPT (A) 12.5/12.5 12.5/12.5/12.5/12.5
Max. Short Circuit Current per MPPT (A) 15.2/15.2 15.2/15.2/15.2/15.2
Number of MPPTs 2 4
Number of Strings per MPPT 1/1 1/1/1/1
AC Output Data (On-grid)
Nominal Apparent Power Output to Utility Grid (VA)
5000 6000 7000 7600 8600
9600
Max. Apparent Power Output to Utility Grid (VA) 5000 6000 7000 7600 8600
9600
Max. Apparent Power from Utility Grid (VA) 6000 7200 8400 9120 9600
9600
Nominal Output Voltage (V) 120/240
Nominal AC Grid Frequency (Hz) 60
Max. AC Current Output to Utility Grid (A) 20.8 25 29.2 31.7 35.8
40
Max. AC Current From Utility Grid (A) 25 30 35 38 40
40
Output Power Factor ~1 (Adjustable from 0.8 leading to 0.8 lagging)
Max. Total Harmonic Distortion <3%
AC Output Data (Back-up)
Back-up Nominal apparent power (VA) 5000 6000 7000 7600 8600
9600
Max. Output Apparent Power (VA) 5000 6000 7000 7600 8600
9600
Peak Output Apparent Power (VA)*
4
6000, 60sec 7200, 60sec 8400, 60sec 9120, 60sec 10320, 60sec
11520, 60sec
Max. Output Current (A) 20.8 25 29.2 31.7 35.8
40
Nominal Output Voltage (V) 120/240
Nominal Output Frequency (Hz) 60
Output THDv (@Linear Load) <3%
Efciency
Max. Efciency 97.6%
CEC Efciency 97.3% 97.4% 97.1% 97.1% 97.1% 97.1%
Max. Battery to Load Efciency 96.6%
Protection
DC Insulation Resistance Detection Integrated
Residual Current Monitoring Unit Integrated
Anti-islanding Protection Integrated
DC Reverse Polarity Protection Integrated
AC Overcurrent Protection Integrated
AC Short Circuit Protection Integrated
AC Overvoltage Protection Integrated
DC Surge Arrester Type III
AC Surge Arrester Type III
DC Switch Integrated
PV String Current Monitoring Integrated
DC Arc Fault Circuit Interrupter Integrated
Rapid Shutdown Integrated
General Data
Operating Temperature Range (°F) -31°F~140°F (>113°F derating)
Relative Humidity 0~95%
Max. Operating Altitude (ft) 13124 ft (>9843 ft derating)
Cooling Method Smart Fan Cooling
User Interface WiFi+APP, LED
Communication with BMS RS485; CAN
Communication with Meter RS485
Communicaiton with Portal Wi-Fi; 4G*
6
(Optional)
Weight (lb) 62.85 70.55
Dimension (W × H × D in) 16.3 × 33.1 × 6.9
Topology Transformerless
Night Power Consumption (W)*
5
<20
DC Connector MC32*1.5
AC Connector MC32*1.5
Protective Class Type 4X
Storage Environments -40°F~+185°F, 0-95%RH, 13124 ft
Mounting Method Wall Bracket
*
1
: Battery discharge/charge power limited by voltage.
*
2
: Inverter will not work when PV input voltage ≥585V.
*
3
: Can be reached only if battery is connected, otherwise the PV start voltage must be greater than 200V.
*
4
: Can be reached only if PV and battery power is enough.
*
5
: No Back-up Output.
*
6
: Estimated launch date: 31/12/2021.
GEH 5-9.6kW
Up to 4 MPPTs Split-phase Hybrid
Single page-20211222-US-V1.0. Information may be subject to change without notice during product improving.
*: GE is a registered trademark of General Electric Company and is used under license by GoodWe Technologies Co., Ltd. © 2021 All Rights Reserved.