Manual
6 49-50300-2  
About the control panel
OPERATING INSTRUCTIONS: Controls
Control Features
1. Display
2. Operating Modes
3. Vacation Mode 
4. Mode Selector
 Use this button to alternate between available modes.
5. Arrow Pads
 Use these buttons to adjust the temperature setting.
6. Enter Key
Use this button to confirm temperature setting following 
adjustment.
7. Filter Reset
 The filter is dirty and requires cleaning when the Red light 
is illuminated. Filter is located on top of the water heater. 
Press button and hold for 5 seconds to reset filter alarm. 
8. Power Saver Override
If operating with a demand response program through a 
local utility company, press and hold to bring unit out of 
Power Saver mode.
9. Appliance Communication Module Port 
 For use with optional ConnectPlus communication module 
(see page 
8 for details). 
10. Anode Reset (on some models) 
When the red light is illuminated, the system has indicated 
that the anode rod is approaching end of life and it is 
recommended to replace it. Press button once to silence 
alarm. Press and hold for 10 seconds to reset the anode 
alarm after replacing. Call GE Appliances Service to 
replace the anode rod. Failure to replace the anode rod 
will void warranty coverage and may result in a tank leak. 
(See page 
12 for instructions to change the anode rod.) 
GE Appliances Service: 888.4GE.HEWH (888.443.4394).
HEAT PUMP
HYBRID
HIGH DEMAND/BOOST
ELECTRIC/STANDARD 
V
ACATION
°F
°C
D
AYS
G
eo
S
pring
Hold for
°F/°C
Hold to
Reset
Hold to Override
PS-Power Saver
Anode
Enter
Filter
Power
Mode
Saver
(on some models)
Displaying Temperature Setpoint
The 
 GeoSpring™ 
control will display the 
temperature setpoint anytime a button on 
the control is pressed. After 30 seconds 
of inactivity, the display will go blank. 
However, the LED indicating the selected 
mode of operation will remain lit. To 
wake the control at any time to see the 
temperature setpoint, press any button on 
the control. 
Turning on the Water Heater
There is no power button for this unit. Once 
the water heater is wired and power is 
supplied, it will be on. The display will show 
the current water temperature setting and 
an LED will illuminate indicating the current 
operating mode. 
To comply with safety regulations, the 
controls are factory preset to 120°F (49°C) 
and Hybrid Mode. It is recommended that 
the unit be set to Heat Pump mode to 
PD[LPL]HHQHUJ\VDYLQJV2SHUDWLQJLQ
Hybrid mode provides a balance of energy 
savings and hot water use convenience. 
Reported energy consumption is based 
on operating the unit in Hybrid mode at 
required Department of Energy (DOE) test 
conditions. Operating at lower temperature 
settings or in Heat Pump mode will provide 
even greater energy savings.
To Adjust the Temperature
Follow these steps:
1. Press the UP or DOWN arrow on 
the control panel key pad to desired 
temperature. 
2. Press ENTER to accept the new setting. 
Note: To change between °F and °C, 
press and hold MODE. 