Full Product Manual
 Install a 1/8” NPT plugged tapping to the dryer 
gas line shut-off valve for checking gas inlet 
pressure.
 Install a flare union adapter to the plugged 
tapping.
 NOTE: Apply pipe compound or PTFE tape 
to the threads of the adapter and plugged 
tapping.
Installation Instructions
 Attach the flexible metal gas line connector to 
the adapter.
B
 Tighten the flexible gas line connection, using 
two adjustable wrenches.
C
D
 Tighten all connections, using two adjustable 
wrenches. Do not overtighten.
E
CONNECTING THE DRYER TO THE GAS 
SUPPLY (cont.)
 Open the gas shut-off valve.
F
Apply pipe compound 
or PTFE tape to all 
male threads.
Shut-Off 
Valve
Plugged 
Tapping
CONNECTING THE DRYER TO THE GAS 
SUPPLY
 Install a female 3/8” NPT elbow at the end of the 
dryer gas inlet.
 Install a 3/8” flare union adapter to the female 
elbow.
   IMPORTANT: Use a pipe wrench to securely hold 
on to the end of the dryer gas inlet to prevent 
twisting the inlet.
 NOTE: Apply pipe compound or PTFE tape to the 
threads of the adapter and dryer gas inlet.
A
Apply pipe compound to the 
adapter and dryer gas inlet.
Elbow
Adapter
Items not supplied
Adapter
1/8” NPT 
Pipe Plug for 
Checking Gas 
Inlet Pressure
Shut-Off Valve
Pipe size at 
least 1/2” 
3/8” NPT
New Metal 
Flexible Gas 
Line Connector
CONNECTING A GAS DRYER (cont.)
20