TEST FOR LEAKS
Never use an open flame to test for gas leaks.
Check all connections for leaks with soapy solution 
or equivalent.
Apply a soap solution. The leak test solution must 
not contain ammonia, which could cause damage 
to the brass fittings.
If leaks are found, close the valve, retighten the 
joint and repeat the soap test.
Ground 
Screw
ELECTRICAL CONNECTION 
INFORMATION FOR GAS DRYERS (cont.)
ELECTRICAL CONNECTION 
INFORMATION FOR GAS DRYERS
- Electrical Shock Hazard
WARNING
Plug into a grounded 3 prong outlet.
DO NOT remove ground prong.
DO NOT use an adapter.
DO NOT use an extension cord.
Failure to do so can result in death, fire or electrical 
shock.
21
•   Circuit – Individual properly polarized and grounded 
15 or 20 amp circuit breaker or time-delay fuse.
•
   Power Supply – 2-wire plus ground, 120 Volt, 
single phase, 60 Hz, alternating current.
•
   Outlet  Receptacle  – 
Properly grounded 
3-prong receptacle to 
be located so the power 
cord is accessible when 
the dryer is in an installed 
position. If a 2-prong 
receptacle is present, it 
is the owner’s responsibility to have a licensed 
electrician replace it with a properly grounded 
3-prong grounding type receptacle. 
Ensure proper 
ground exists 
before use.
GROUNDING INSTRUCTIONS
This dryer must be grounded. In the event of a 
malfunction or breakdown, grounding will reduce 
the risk of electric shock by providing a path of 
least resistance for electric current. This dryer uses 
a cord having an equipment-grounding conductor 
and a grounding plug. The plug must be plugged 
into an appropriate outlet that is properly installed 
and grounded in accordance with all local codes 
and ordinances.
WARNING
Improper connection of the 
equipment-grounding conductor 
can result in a risk of electric shock. Check with a 
qualified electrician, or service representative or 
personnel, if you are in doubt as to whether the 
appliance is properly grounded. DO NOT modify the 
plug on the power supply cord. If it will not fit the 
outlet, have a proper outlet installed by a qualified 
electrician. 
SAVE THESE INSTRUCTIONS
•   Dryer must be electrically grounded in 
accordance with local codes and ordinances, 
or in the absence of local codes, with the latest 
edition of the NATIONAL ELECTRICAL CODE, 
ANSI/NFPA NO. 70 or CANADIAN ELECTRICAL 
CODE, CSA C22.1. Check with a licensed 
electrician if you are not sure that the dryer is 
properly grounded.
•
   If required by local codes, an external 18 gauge 
or larger copper ground wire (not provided) 
may be added. Attach to dryer cabinet with a 
#8-18 x ½” sheet metal screw (available at any 
hardware store) to rear of dryer as illustrated.