Full Product Manual
Installation Instructions
CONNECTING DRYER USING 3-WIRE 
CONNECTION
CONNECTING AN ELECTRIC DRYER (cont.)
3-wire Connection
Not for use in Canada.
DO NOT use for Mobile Home Installations.
NOT for use on new construction.
NOT for use on recreational vehicles.
NOT for use in areas where local codes prohibit 
grounding through the neutral conduction.
1.
 Turn off the circuit breaker(s) (30 amp) or remove 
the dryer’s circuit fuse at the electrical box.
2.
 Be sure the dryer cord is unplugged from the wall 
receptacle.
3.
 Remove the power cord cover located at the 
lower back.
4.
 Install 3/4-in. UL-recognized strain relief to power 
cord entry hole. Bring power cord through strain 
relief. 
5.
 Connect power cord as follows:
  A. Connect the 2 hot lines to the outer screws of 
the terminal block (marked L1 and L2).
  B. Connect the neutral (white) line to the center of 
the terminal block (marked N).
6.
 Be sure ground strap is connected to neutral 
(center) terminal of block and to green ground 
screw on cabinet rear. Tighten all terminal block 
screws (3) securely.
7.
 Properly secure power cord to strain relief.
8.
 Reinstall the cover.
CONNECTING DRYER USING 4-WIRE 
CONNECTION (MUST BE USED FOR 
MOBILE HOME INSTALLATION)
NOTE: Since January 1, 1996, the National Electrical 
Code requires that new constructions use a 4-wire 
connection to an electric dryer. A 4-wire cord must 
also be used where local codes do not permit 
grounding through the neutral.
3-wire connection is NOT for use on new 
construction.
1.
 Turn off the circuit breaker(s) (30 amp) or remove 
the dryer’s circuit fuse at the electrical box.
2.
 Be sure the dryer cord is unplugged from the wall 
receptacle.
3.
 Remove the power cord cover located at the 
lower back.
4.
 Remove and discard ground strap. Keep the 
green ground screw for Step 7.
5.
 Install 3/4 in. UL-recognized strain relief to power 
cord entry hole. Bring power cord through strain 
relief. 
6.
 Connect power cord as follows:
  A. Connect the 2 hot lines to the outer screws of 
the terminal block (marked L1 and L2).
  B. Connect the neutral (white) line to the center of 
the terminal block (marked N).
7.
 Attach ground wire of power cord with the green 
ground screw (hole above strain relief bracket). 
Tighten all terminal block screws (3) securely.
8.
 Properly secure power cord to strain relief.
9.
 Reinstall the cover.
Remove ground 
strap and 
discard. Keep 
green ground 
screw
Hot Wire
Relocate green 
ground screw here
Green Wire
Strain Relief 
Bracket
3/4” UL Recognized 
Strain Relief
Hot Wire
Neutral 
(white)
Screw
Cover
4 #10 AWG minimum copper 
conductors or 120/240V 30A 
power supply cord kit marked 
for use with dryers and provided 
with closed loop or spade 
terminals with upturned ends 
(not supplied)
Screws
If required, 
by local code, 
install external 
ground (not 
provided) to 
grounded metal, 
cold water 
pipe, or other 
established 
ground 
determined 
by a qualified 
electrician.
Hot Wire
Strain 
Relief 
Bracket
3/4” UL Recognized 
Strain Relief
Hot 
Wire
Neutral 
(white)
Screws
Cover
3 #10 AWG minimum copper 
conductors or 120/240V 30A 
power supply cord kit marked for 
use with dryers and provided with 
closed loop or spade terminals 
with upturned ends (not supplied)
Green Ground 
Screw
Ground 
Strap
Screw
NEVER LEAVE THE COVER OFF OF THE TERMINAL 
BLOCK.
NEVER LEAVE THE COVER OFF OF THE TERMINAL 
BLOCK.