Full Product Manual
Installation Instructions
EXHAUSTING THE DRYER
EXHAUST SYSTEM CHECKLIST
HOOD OR WALL CAP
•
  Terminate in a manner to prevent back drafts or entry 
of birds or other wildlife.
•
  Termination should present minimal resistance to 
the exhaust airflow and should require little or no 
maintenance to prevent clogging.
•
  Wall caps must be installed at least 12” above ground 
level or any other obstruction with the opening 
pointed down.
•
Never vent the dryer out of the roof.
SEPARATION OF TURNS
•
  For best performance, separate all turns by at least 
4 ft. of straight duct, including distance between last 
turn and dampened wall cap. 
SEALING OF JOINTS
•
  All joints should be tight to avoid leaks. The male end 
of each section of duct must point away from the 
dryer.
•
  Duct joints should be made air- and moisture-tight 
by wrapping the overlapped joints with duct tape or 
aluminum tape.
•
Do not assemble ductwork with any fasteners 
that extend into the duct. These fasteners can 
accumulate lint, creating a potential fire hazard.
•  Horizontal runs should slope down towards the 
outdoors 1/4” per foot.
• 
Provide an access for inspection and cleaning of 
the exhaust system, especially at turns and joints. 
Exhaust system shall be inspected and cleaned at 
least once a year.
INSULATION
•
  Ductwork that runs through an unheated area or is 
near air conditioning should be insulated to reduce 
condensation and lint buildup.
TOOLS AND MATERIALS YOU WILL NEED TO INSTALL EXHAUST DUCT
 Phillips-head screwdriver
 Duct tape or duct 
clamp
 Rigid or UL-listed 
flexible metal 4” (10.2 
cm) duct
 Drill with 1/8” drill bit 
(for bottom venting)
 Hacksaw
 Vent hood
25
- Fire Hazard
WARNING
This dryer MUST be vented to the outdoors.
Use only 4” rigid metal ducting for the home 
exhaust duct.
Use only 4” rigid metal or UL-listed dryer transition 
duct to connect the dryer to the home exhaust.
DO NOT use a plastic vent.
DO NOT exhaust into a chimney, kitchen exhaust, 
gas vent, wall, ceiling, attic, crawl space, or 
concealed space of a building.
DO NOT install a screen in or over the exhaust duct.
DO NOT install a booster fan in the exhaust duct.
DO NOT use duct longer than specified in the 
exhaust length table.
Failure to follow these instructions can result in 
death or fire.
PARTS AVAILABLE FROM GEAPPLIANCES.COM
OR LOCAL SERVICE ORGANIZATIONS
PM8X85  
Outdoor exhaust hood
PM08X10085  
8’ Flexible metal clothes dryer 
transition duct with 2 clamps
WX08X10130  
4” Dryer exhaust clamp
WE49X22606  
Rear exhaust opening cover, for side 
or bottom vented dryers