109108108
READING NOMENCLATURES (continued)
AH11H09D3B
Unit Series
Chassis Series
Unit Type
E= cooling with electric
resistance heat
H= cooling/heat pump
with backup electric
heat
HOTPOINT® COMFORT PRODUCT
Brand
H=Hotpoint
PTAC
Nominal Cooling Capacity
07=7,000 BTUH
09=9,000 BTUH
12=12,000 BTUH
15=15,000 BTUH
Special Features
B=base unit
Voltage/Phase/Frequency
D= 230/208 volt, single
phase, 60 Hz
E= 265 volt, single phase,
60 Hz
Heater
Watts/Amps
3=3.45 kW; 20 amp
HWF05XCP
Feature/
Appearance
F= OPP 5K
R= Electronic
w/ remote
E= High
Efficiency
Unit Type
W=Window AC
TW= Through the Wall AC
HAIER COMFORT PRODUCT
Brand
Q= Haier
BTUs in 1000s
05= 5,000 BTU
06= 6,000 BTU
08= 8,000 BTU
10= 10,000 BTU
12= 12,000 BTU
15= 15,000 BTU
24= 24,000 BTU
Model Year
Voltage
X= 115 Volt
V= 230/208 Volt
Cool or Heat/Cool
C= 115 Volt
H= 230/208 Volt
HPN10XCM
Appearance
by Factory
N Design
D Design
F Design
Y Design
P Design
RB Design
B Design
A Design
AC Type
P= Portable AC
HAIER PORTABLE AIR CONDITIONER
Brand
Q=Haier
C= Commercial
Cool
BTUs in 1000s
08= 8,000 BTU
10= 10,000 BTU
12= 12,000 BTU
14= 14,000 BTU
Model Year
Voltage
X= 115 Volt
V= 230/208 Volt
Cool or Heat/Cool
C= 115 Volt
H= 230/208 Volt
HM70EP
Feature/
Appearance
M= Design
HAIER DEHUMIDIFIER
Brand
Q=Haier
C= Commercial
Cool
Pint Size
30= 30 Pint
45= 45 Pint
50= 50 Pint
65= 65 Pint
70= 70 Pint
Model Year
Designator
E= Energy Star
DE45EM
Feature/
Appearance
M=Design
Product Type
D=Dehumidifier
Pint Size
30= 30 Pint
45= 45 Pint
50= 50 Pint
65= 65 Pint
70= 70 Pint
Model Year
E= Energy Star
HAIER DUCTLESS TEMPO SERIES SINGLE ZONE SYSTEMS
HAIER
09TE1 12TE1 09TE2 12TE2 18TE2 24TE2
Outdoor Unit 1U09TE1VHA 1U12TE1VHA 1U09TE2VHA 1U12TE2VHA 1U18TE2VHA 1U24TE2VHA
Indoor Unit AW09TE1VHA AW12TE1VHA AW09TE2VHA AW12TE2VHA AW18TE2VHA AW24TE2VHA
SPECIFICATIONS
Operating range (°F) Cooling °F (°C) 14~11F (-10~46°C) 14~11F (-10~46°C) -4-11F (-20~4C) -4-11F (-20~4C) 0~115°F (-18~46°C) 0~11F (-18~4C)
Heating °F (°C) -4~75°F (-20-2C) -4~75°F (-20-2C) -4~75°F (-20-2C) -4~75°F (-20-2C) -4~75°F (-20-2C) -4~75°F (-20-24°C)
COOLING
Rated capacity Btu/hr 9,000 12,000 9,000 12,000 18,000 24,000
Capacity range Btu/hr 3,800~12,000 4,100~12,500 3,800~10,000 4,100~13,000 5,000~19,000 6,500~26,000
Rated power input W 810 1,200 800 1,100 1,650 2,150
SEER/EER 16/11.0 16/11.0 18/11.0 18/11.0 16/10.0 16/10.0
Moisture removal gal./hr 2.5 3.4 2.3 3.4 4.2 5.9
HEATING
Heating Capacity Range Btu/hr 4,100~12,000 4,500~16,000 4,100~11,000 4,500~13,000 5,400~22,000 6,800~28,000
Rated Heating Capacity 47°F Btu/hr 10,000 12,000 10,000 12,000 19,000 26,000
COP 3.25 2.93 4.15 3.79 3.22 3.22
Rated Heating Capacity 17°F Btu/hr 5,600 7, 800 5,000 7,5 00 11,200 16,600
Max. Heating Capacity 17°F Btu/hr 7,50 0 11,200 7,500 10,000 16,900 20,700
Max. Heating Capacity 5°F Btu/hr 6,900 8,930 6,000 8,500 13,600 16,400
Max. Heating Capacity -F Btu/hr 5,300 7,100 5,000 7,500 11,200 13,800
Rated Power Input W 850 1,000 750 980 1,700 2,400
HSPF 9.0 9.0 10
10 9.0 9.0
OUTDOOR UNIT
Maximum fuse size A 20 20 15 15 20 25
Minimum circuit amp A 18 18 12 12 17 19
Outdoor noise level dB 47 50 48 50 56 53
Dimension: height in (mm) 21-1/4 (540) 21-1/4 (540) 21 -3/4 (553) 2 1-3/4 (553) 27-7/16 (697) 30 (762)
Dimension: width in (mm) 30-11/16 (780) 30-11/16 (780) 31-1/2 (800) 31-1/2 (800) 35 (890) 36-3/16 (920)
Dimension: depth in (mm) 9-5/8 (245) 9-5/8 (245) 10-7/8 (275) 10-7/8 (275) 13-7/8 (353) 15-1/8 (385)
Weight (Ship/Net)- lbs (kg) 66.2/58.4 (30/26.5) 71.7/63.9 (32.5/29) 76.1/63.5 (34.5/28.8) 82.2/69.7 (37.3/31.6) 105.8/97.0(48.0/44.0) 121.3/112.5 (55.0/51.0)
INDOOR UNIT
Fan speed stages 5 + Auto 5 + Auto 5 + Auto 5 + Auto 5 + Auto 5 + Auto
Airflow CFM
(Turbo/High/Med/Low/Quiet)
305/295/280/
265/240
310/300/287/
275/245
421/332/292/
242/200
426/360/310/
265/200
545/530/505/
475/460
665/650/610/
570/555
Indoor sound level dB
(Turbo/High/Med/Low/Quiet) 39/37/33/28/23 39/37/33/28/23 42/36/33/29/26 42/38/34/31/26 45/43/39/36/33 47/45/40/37/34
Dimension: height in (mm) 11 -7/ 16 (290) 11-7/16 (29 0) 11-7/8 (301) 11-7/8 (301) 12-1/2 (318) 13-3/16 (335)
Dimension: width in (mm) 34 (864) 34 (864) 33 -3/4 (856) 33-3/4 (8 56) 39-11/16 (1008) 44-5/16 (1125)
Dimension: depth in (mm) 7 -7/8 (200) 7 -7/8 (200) 7-3/4 ( 1 96) 7-3/4 ( 1 96) 8-7/8 (225) 9 -7/ 16 (240)
Weight (Ship/Net)- lbs (kg) 24.7/19.9 (11.2/9.0) 24.7/19.9 (11.2/9.0) 26.9/21.2 (12.2/9.6) 26.9/21.2 (12.2/9.6) 33.1/26.5 (15.0/12.0) 38.6/30.9 (17.5/14.0)
REFRIGERANT LINES
Connections Flare Flare Flare Flare Flare Flare
Liquid O.D. in 1/4 1/4 1/4 1/4 1/4 1/4
Suction O.D. in 3/8 3/8 3/8 3/8 1/2 1/2
Factory charge Oz 26.5 35.3 32.8 40.6 40.6 67.0
Maximum line length Ft / m 66/20 66/20 66/20 66/20 83/25 83/25
Maximum height Ft / m 33/10 33/10 33/10 33/10 50/15 50/15
GE BUILT-IN/THROUGH-THE-WALL AIR CONDITIONER
AJCQ10ACG
Type
C=cooling
E= electric heat
Unit Series
M= high-mount
chassis with
electronic
remote
Q= cooling with
remote control
Category
J= 26" through-the-wall
units
K= 24" through-the-wall
units
Capacity
Nominal BTUs in 1000s
Configuration
C=chassis only
Voltage/Amps
L= 115V, 60Hz,
<7.0 amps
A= 115V, 60Hz,
>7.5 amps
D= 230/208V, 60Hz,
all amperages
Market
Generation
Brand
A= GE
AZ65H12DAD
Chassis series
45= cool/electric
heat
65=heat pump
Unit type
E= cooling with electric
resistance heat
H= heat pump with
electric resistance
heat
GE ZONELINE® CHASSIS
Zoneline
Nominal cooling
capacity
07=7,000 BTUH cooling
09=9,000 BTUH cooling
12=12,000 BTUH cooling
15=15,000 BTUH cooling
Special features
B=base unit
C= corrosion treated
D= internal condensate
removal (ICR) (AZ65
only)
P=Dry Air 25 (AZ45 only)
M=Makeup Air
Voltage/Phase/
Frequency
D= 230/208 volt, single
phase, 60 Hz
E= 265 volt, single phase,
60 Hz
Universal power
connection
A= These models have
universal power
connection
B= Digital Makeup Air
module with universal
power connection
AZ91H12D3E
Chassis series
91= heat pump
single packaged
vertical unit
Unit type
H= heat pump with
electric resistance
heat
ZONELINE VERTICAL UNIT
Zoneline
Nominal cooling
capacity
09=9,000 BTUH cooling
12=12,000 BTUH cooling
18=18,000 BTUH cooling
Special features
E=corrosion treated
Voltage/Phase/Frequency
D= 230/208 volt, single
phase, 60 Hz
E= 265 volt, single phase,
60 Hz
Heater
wattage/Amps
2=2.4 kW; 15 amp
3=3.4 kW; 20 amp
5=5.0 kW; 30 amp
Brand
A= GE
Q=Haier
GE PORTABLE AIR CONDITIONER
APCA12NXMS
Product
P= Portable
AC
Type
C=cool only, single hose
S=heat/cool, single hose
D=cool only, dual hose
H=heat/cool, dual hose
Color
B=Black
G=Stratus
Gray
W=White
S=Silver
Capacity BTU/hr
BTU/hr in 1000s
Unit Series
Market
Generation
X=2018
Y=2019
Z=2020
A=2021
Features
M=field
Basis for rating
A=ASHRAE BTU
D=DOE SACC
GE DEHUMIDIFIER
Market
Generation
Voltage
L= 115V, <7.5 amps
Product
D=dehumidifier
P=dehumidifier with built-in pump
APER70LW
Capacity
70 pints/day
Brand
A= GE
Unit Series Features