Brochure

geappliances.com
15
VRF
COMMERCIAL AC DUCTLESS
WATER HEATERS WATER TREATMENT
ROOM AC
SPECIFICATIONS
14
ZONELINE® PACKAGED TERMINAL AIR CONDITIONERS
Specifications subject to change.
Complete features and specifications on pages 129-134.
*Coefficient of Performance
*Included with 265V Zoneline
• Digital LED display
Variable fresh air vent
control
• Cross-ow blower
• Two DC fan motors
• Smart fan cooling
Heat and Freeze
Sentinel
Remote thermostat
capability
Electronic
temperature limiting
Works with central
desk control and
through wall fans
AZ45 SERIES | GE COOLING AND ELECTRIC HEAT
AZ45E07DAC
7,200/7,000 BTU
13.4/13.4 EER
230/208 Volts
AZ45E09DAC
9,400/9,300 BTU
11.8/11.8 EER
230/208 Volts
AZ45E12DAC
11,600/11,500 BTU
11.7/11.8 EER
230/208 Volts
AZ45E15DAC
14,000/13,900 BTU
10.3/10.4 EER
230/208 Volts
AZ45E07EAC
7,1 00 BTU
13.2 EER
265 Volts
AZ45E09EAC
9,500 BTU
11.6 EER
265 Volts
AZ45E12EAC
11,500 BTU
11.7 EER
265 Volts
AZ45E15EAC
14,700 BTU
10.5 EER
265 Volts
AZ45E07DAB
7,200/7,000 BTU
13.4/13.4 EER
230/208 Volts
AZ45E09DAB
9,700/9,600 BTU
12.1/12.1 EER
230/208 Volts
AZ45E12DAB
11,600/11,500 BTU
11.7/11.8 EER
230/208 Volts
AZ45E15DAB
14,200/14,100 BTU
10.5/10.5 EER
230/208 Volts
AZ45E07DAP
6,900/6,800 BTU
12.8/12.8 EER
230/208 Volts
AZ45E09DAP
9,400/9,300 BTU
12.1/12.1 EER
230/208 Volts
AZ45E12DAP
11,200/11,000 BTU
11.4/11.5 EER
230/208 Volts
AZ45E09EAP
9,400 BTU
12.1 EER
265 Volts
AZ45E12EAP
10,900 BTU
11.0 EER
265 Volts
BASE PREMIUM GUARD CORROSION PROTECTION DRY AIR 25 WITH CORROSION PROTECTION
Includes all resistance
heat features, plus:
• Staged heating
Heat pump with
backup resistance
heat option
• Reverse cycle defrost
AZ65 SERIES | GE HEAT PUMP
AZ65H07DAB
7,100/6,900 BTU cool
6,200/6,100 BTU heat
13.0/13.0 EER
4.0/4.0 COP*
230/208 Volts
AZ65H09DAB
9,700/9,600 BTU cool
8,100/8,000 BTU heat
12.2/12.2 EER,
3.7/3.7 COP*
230/208 Volts
AZ65H12DAB
11,900/11,800 BTU
cool 10,400/10,300
BTU heat 11.6/11.8 EER
3.6/3.6 COP*
230/208 Volts
AZ65H15DAB
14,400/14,200 BTU
cool 13,500/13,300
BTU heat
10.5/10.5 EER
3.2/3.2 COP*
230/208 Volt
BASE PREMIUM GUARD CORROSION PROTECTION INTERNAL CONDENSATE REMOVAL
AZ65H07DAC
7,100/7,000 BTU cool
6,200/6,100 BTU heat
13.0/13.0 EER
4.0/4.0 COP*
230/208 Volts
AZ65H09DAC
9,600/9,500 BTU cool
8,100/8,000 BTU heat
12.2/12.2 EER
3.7/3.7 COP*
230/208 Volts
AZ65H12DAC
11,800/11,600 BTU
cool 10,300/10,200
BTU heat
11.8/11.8 EER
3.6/3.6 COP*
230/208 Volts
AZ65H15DAC
14,400/14,200 BTU
cool 13,200/13,000
BTU heat
10.4/10.4 EER
3.2/3.2 COP*
230/208 Volts
AZ65H07EAC
7,000 BTU cool
6,200 BTU heat
12.8 EER
3.9 COP*
265 Volts
AZ65H09EAC
9,500 BTU cool
8,100 BTU heat
11.7 EER
3.6 COP*
265 Volts
AZ65H12EAC
11,500 BTU cool
10,000 BTU heat
11.2 EER
3.5 COP*
265 Volts
AZ65H15EAC
14,000 BTU cool
13,200 BTU heat
10.0 EER
3.1 COP*
265 Volts
AZ65H07DAD
7,000/6,900 BTU cool
6,200/6,000 BTU heat
13.0/13.0 EER
4.0/4.0 COP*
230/208 Volts
AZ65H09DAD
9,600/9,500 BTU cool
8,200/8,000 BTU heat
12.0/12.0 EER
3.6/3.6 COP*
230/208 Volts
AZ65H12DAD
11,800/11,600 BTU
cool, 10,400/10,200
BTU heat, 11.5/11.5 EER
3.5/3.5 COP*
230/208 Volts
AZ65H15DAD
14,100/14,100 BTU cool
13,200/13,000 BTU heat
10.3/10.3 EER
3.2/3.2 COP*
230/208 Volts
AZ65H07EAD
7,000 BTU cool
6,200 BTU heat
12.8 EER
3.9 COP*
265 Volts
AZ65H09EAD
9,500 BTU cool
8,100 BTU heat
11.7 EER
3.5 COP*
265 Volts
AZ65H12EAD
11,600 BTU cool
10,000 BTU heat
11.4 EER
3.4 COP*
265 Volts
AZ65H15EAD
14,200 BTU cool
13,300 BTU heat
10.3 EER
3.2 COP*
265 Volts
ADDITIONAL ACCESSORIESMAY BE REQUIRED FOR AZ45/AZ65 SERIES ZONELINE UNITS
MODEL # DESCRIPTION
RAA13 MERV 13 replacement air filter for RAK13 kit
RAB71B Wall sleeve
RAB7116B Wall sleeve, 16", 45 & 65 only
RAB7118B Wall sleeve, 18", 45 & 65 only
RAB7120B Wall sleeve, 20", 45 & 65 only
RAB7124B Wall sleeve, 24", 45 & 65 only
RAB78B Wall sleeve, 45 & 65 only
RAB81 Quick Snap wall sleeveunassembled
RAB81B Quick Snap wall sleeve—assembled
RAD10 Internal/external drain kit
RAG60 Stamped aluminum grille
RAG61/62/63
Architectural exterior grille(s), high-impact plastic.
Beige, Maple and Dark Brown
RAG67 Extruded aluminum architectural grille
RAK13 MERV 13 Makeup air filter kit for AZ45/65 DBM/EBM models
RAK148D2
Programmable dual-use single fan speed thermostat.
Can be set up for single- or two-stage heating.
RAK149P2
RAK149F2
Two fan speed dual use digital thermostat. Can be set up for
single- or-two-stage heat.
RAK180W1
Wired/wireless wall thermostat with motion sensor,
MUAM capable
RAK315D
230/208V power connection kit (15 amp) for
direct-connected units
RAK320D
230/208V power connection kit (20 amp)
for direct-connected units
RAK44 Curtain Guard (5pk)
MODEL # DESCRIPTION
RAK330D
230/208V power connection kit (30 amp)
for direct-connected units
RAK315P 230/208V LCDI power cord connection kit (15 amp)
RAK320P 230/208V LCDI power cord connection kit (20 amp)
RAK330P 230/208V LCDI power cord connection kit (30 amp)
RAK4002D Zoneline direct -connect junction box (230V)*
RAK515D
265V power connection kit (15 amp) for
direct-connected units
RAK520D
265V power connection kit (20 amp) for
direct-connected units
RAK530D
265V power connection kit (30 amp) for
direct-connected units
RAK204D15C 230/208V sub-base with (15 amp) power cord included
RAK204D20C 230/208V sub-base with (20 amp) power cord included
RAK204D30C 230/208V sub-base with (30 amp) power cord included
RAK204U 230/208V non-electrical sub-base
RAK204E15C 265V sub-base with (15 amp) power cord included
RAK204E20C 265V sub-base with (20 amp) power cord included
RAK204E30C 265V sub-base with (30 amp) power cord included
RAK204SW
Disconnect Switch for use in sub-base
DPST switch that fits directly into sub-base for use in
230/208 and 265 volt applications.
RAK315SP
230/208V power cord connection kit (15 amp) for sub-base
connected units
RAK320SP
230/208V power cord connection kit (20 amp) for sub-base
connected units
RAK330SP
230/208V power cord connection kit (30 amp) for sub-base
connected units
RAK515P
265V power cord connection kit (15 amp) for
sub-base connected units
RAK520P
265V power cord connection kit (20 amp) for
sub-base connected units
RAK530P
265V power cord connection kit (30 amp) for
sub-base connected units
NOTE: Because makeup air increases
room BTU load requirements and requires
additional PTAC cooling or heating, the
building’s electrical needs may be impacted.
NOTE: Makeup air models are not
recommended for installation within two
miles of coastal areas.
NOTE: It is strongly recommended to install
makeup air with wall thermostats.
AZ45 SERIES | GE COOLING AND ELECTRIC HEAT WITH MAKEUP AIR
AZ65 SERIES | GE HEAT PUMP WITH MAKEUP AIR
AZ45E09DBM
9,100/9,100 BTU
11.5/11.5 EER
230/208 Volts
AZ45E12DBM
11,700/11,500 BTU
11.6/11.6 EER
230/208 Volts
MAKEUP AIR
AZ65H07DBM
7,000/7,000 BTU cool
6,200/6,100 BTU heat
12.5/12.5 EER
4.0/4.0 COP*
230/208 Volts
AZ65H09DBM
9,200/9,100 BTU cool
8,000/7,900 BTU heat
11.3/11.3 EER
3.3/3.3 COP*
230/208 Volts
AZ65H12DBM
11,500/11,400 BTU
cool, 10,200/10,000
BTU heat, 11.2/11.2 EER
3.5/3.5 COP*,
230/208 Volts
AZ65H15DBM
14,000/13,800 BTU
cool, 13,200/13,000
BTU heat, 10.1/10.1 EER,
3.2/3.2 COP*
208/230 Volts
AZ65H07EBM
6,900 BTU cool
6,000 BTU heat
12.5 EER
3.9 COP*
265 Volts
AZ65H09EBM
9,200 BTU cool
8,100 BTU heat
11.5 EER
3.6 COP*
265 Volts
AZ65H12EBM
11,600 BTU cool
10,000 BTU heat
11.3 EER
3.4 COP*
265 Volts
MAKEUP AIR
Includes all AZ45 features, plus:
Delivers 25-50 CFM of continuous
makeup air
Dehumidifies incoming air when
outdoor relative humidity is above
55% and outdoor temperatures are
above 50° F
• Motorized vent door
• May reduce the need for rooftop units
Includes all resistance heat makeup
air features, plus:
• Staged heating
Heat pump with backup
resistance heat option
• Reverse cycle defrost
*Coefficient of Performance