Quick Start Manual
4
Installation Preparation
PREPARE ELECTRICAL WIRING
WARNING
FOR PERSONAL SAFETY: Remove house 
fuse or open circuit breaker before 
beginning installation. Do not use an 
extension cord or adapter plug with this 
appliance.
ADVERTENCIA
ADVERTENCIA PARA SEGURIDAD 
PERSONAL: Quite el fusible o abra el 
interruptor de circuitos antes de comenzar 
la instalación. No utilice un cable de 
extensión o un enchufe adaptador con 
este artefacto. 
Electrical Requirements
•This appliance must be supplied with 120V, 60Hz., and
connected to an individual properly grounded branch
circuit, protected by a 15 or 20 ampere circuit breaker
or time delay fuse.
•Wiring must be 2 wire with ground.
•If the electrical supply does not meet the above
requirements, call a licensed electrician before
proceeding.
Grounding Instructions—Cable Direct
This appliance must be connected to a grounded metal, 
permanent wiring system, or an equipment grounding 
conductor must be run with the circuit conductors and be 
connected to the equipment grounding terminal or lead on the 
appliance.
Grounding Instructions—Power Cord Models
This appliance must be grounded. In the event of a
malfunction or breakdown, grounding will reduce the risk of 
electrical shock by providing a path of least resistance for 
electric current. The plug must be plugged into an appropriate 
outlet that is installed and grounded in accordance with local 
codes and ordinances.
WARNING
The improper connection of the
equipment grounding conductor can 
result in a risk of electric shock. Check 
with a qualified electrician or service 
representative if you are in doubt that the 
appliance is properly grounded.
ADVERTENCIA
La conexión inadecuada del conductor de 
conexión a tierra del equipamiento puede 
provocar un riesgo de descarga eléctrica. 
Consulte a un electricista calificado o 
representante de servicio técnico si tiene 
dudas sobre la correcta conexión a tierra 
del aparato. 
Cabinet Preparation & Wire Routing
•The wiring may enter the opening from either side,
rear or the floor within the shaded area.
•Cut a 1-1/2” max. dia. hole to admit the electrical cable. The 
hole must be free of sharp edges. If the cabinet wall is metal, 
the hole edge must be covered with a bushing.
•Cable direct connections may pass through the same hole as 
the drain hose and hot water line, if convenient. If cabinet wall 
is metal, the hole edge must be covered with a bushing.
NOTE: Power cords with plug must pass through a separate 
hole.
Electrical Connection to Dishwasher
Electrical connection is on the right front of dishwasher .
•For cable direct connections the cable must be routed as 
shown in Figure 5. Cable must extend a minimum of 24”from 
the rear wall.
•For power cord connections, install a 3-prong grounding type 
receptacle. The power-supply receptacle for the appliance 
shall be installed in a cabinet or on a wall adjacent to the 
undercounter space in which the appliance is to be installed.
Figure 5
White
24"
from Wall
3"
from
Cabinet
Ground
Black
1-1/2" Dia.
Hole (Max.)