Specification Sheet
GTD33GASK 
GE
Appliances
7.2 Cu. Ft. Capacity Aluminized  
Alloy Drum Gas Dryer
For answers to your Monogram, GE Café
™
 Series, GE Profile
™
 Series or 
GE Appliances product questions, visit our website at geappliances.com 
or call GE Answer Center
®
 Service, 800.626.2000.
Specification Created 1/16
EXHAUST OPTION: When viewed from the 
front of the unit, exhaust 3-way via rear, left 
and bottom. Dryer is shipped exhausted to 
the rear. Alternate exhausting knockouts are 
supplied.
GAS: An individual, properly-grounded 
branch circuit, with a three-prong grounding-
type receptacle, protected by a 15 or 20 amp 
circuit breaker or a time-delay fuse is required.
GAS DRYER ELECTRIC RATING:  
120V, 60Hz, 6A
GAS (BTU/HR): 22,000. Factory-equipped 
for natural gas. Tested for LP gas. LP gas 
supply requires a conversion kit. Check 
installation instructions for correct kit and 
have a qualified gas technician install a 
conversion kit. See dryer ducting information 
for proper installation.
NOTE: Dryer wall outlet must be located 
within 36" of service cord entry and accessible 
when dryer is mounted in position.
INSTALLATION INFORMATION : 
For complete information, see installation 
instructions packed with your dryer.
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
22 1/2"
26 3/4"
4"
1 3/4"
3 1/4"
4 1/4"
37 1/2"
44"
27"
5"
POWER CORD 4 1/2"
11 3/4"
SIDE VIEW
REAR VIEW
SPECIAL INSTALLATION REQUIREMENTS
ALCOVE OR CLOSET INSTALLATION: 
- If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.
- The dryer MUST be exhausted to the outside.
- Minimum clearances between dryer cabinet and adjacent walls or other surfaces are: 0" either side; 3" front 
and rear
- Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".
- Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area 
equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 
sq. in. of open area equally distributed.
-   No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
BATHROOM OR BEDROOM INSTALLATION:
- The dryer MUST be exhausted to the outdoors.
- The installation must conform with the local codes, or in the absence of local codes, with the National Electric 
Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
MINIMUM CLEARANCES OTHER THAN ALCOVE OR CLOSET INSTALLATION:
- Minimum clearances to combustible surfaces are: 0" both sides; 3" rear
DRYER EXHAUSTING INFORMATION :  
Use metal duct only, vertical and horizontal ducting.