CONNECTING AN ELECTRIC DRYER (cont.) 
(Skip for gas dryers and if your dryer already has a power cord attached)
Installation Instructions
ELECTRICAL CONNECTION 
INFORMATION FOR ELECTRIC DRYERS
- Fire Hazard
WARNING
Use a new UL-listed 240V 30 amp dryer power supply 
cord with closed ring terminals or spade terminals with 
upturned ends.
Use a UL-listed strain relief.
Disconnect power before making electrical 
connections. 
Connect neutral wire (white or center wire) to center 
terminal.
Ground wire (green or bare wire) must be connected to 
green ground connector. 
Connect remaining two supply wires to remaining two 
terminals.
Securely tighten all electrical connections.
Replace the terminal block cover.
Failure to do so can result in death, fire or electrical 
shock.
For electrical connections using a 
power cord:
ELECTRICAL CONNECTION 
INFORMATION FOR ELECTRIC DRYERS
For direct wire connections:
- Fire Hazard
WARNING
Use 10 gauge copper wire.
Use a UL-listed strain relief.
Disconnect power before making electrical 
connections. 
Connect neutral wire (white or center wire) to center 
terminal.
Ground wire (green or bare wire) must be connected to 
green ground connector. 
Connect remaining two supply wires to remaining two 
terminals.
Securely tighten all electrical connections.
Replace the terminal block cover.
Failure to do so can result in death, fire or electrical 
shock.
GROUNDING INSTRUCTIONS
For a grounded, cord-connected dryer: This dryer 
must be grounded. In the event of a malfunction 
or breakdown, grounding will reduce the risk 
of electric shock by providing a path of least 
resistance for electric current. This dryer uses a 
cord having an equipment-grounding conductor 
and a grounding plug. The plug must be plugged 
into an appropriate outlet that is properly installed 
and grounded in accordance with all local codes 
and ordinances.
WARNING
Improper connection of the 
equipment-grounding conductor 
can result in a risk of electrical shock. Check with a 
qualified electrician, or service representative or 
personnel, if you are in doubt as to whether the 
appliance is properly grounded. DO NOT modify the 
plug on the power supply cord. If it will not fit the 
outlet, have a proper outlet installed by a qualified 
electrician. 
SAVE THESE INSTRUCTIONS
GROUNDING INSTRUCTIONS
For a permanently connected dryer: This 
dryer must be connected to a grounded metal, 
permanent wiring system, or an equipment-
grounding conductor must be run with the circuit 
conductors and connected to the equipment-
grounding terminal on the appliance.
WARNING
Improper connection of the 
equipment-grounding conductor 
can result in a risk of electrical shock. Check with a 
qualified electrician, or service representative or 
personnel, if you are in doubt as to whether the 
appliance is properly grounded.
SAVE THESE INSTRUCTIONS
10