Installation Guide
Installation Instructions
CONNECTING DRYER USING 3-WIRE 
CONNECTION
1. Turn off the circuit breaker(s) (30 amp) or remove the 
dryer’s circuit fuse at the electrical box.
2. Be sure the dryer cord is unplugged from the wall 
receptacle.
3. Remove the power cord cover located at the lower 
back.
4. Install 3/4-in. UL-recognized strain relief to power 
cord entry hole. Bring power cord through strain 
relief. 
5. Connect power cord as follows:
  A. Connect the 2 hot lines to the outer screws of the 
terminal block (marked L1 and L2).
  B. Connect the neutral (white) line to the center of the 
terminal block (marked N).
6. Be sure ground strap is connected to neutral (center) 
terminal of block and to green ground screw on 
cabinet rear. Tighten all terminal block screws (3) 
securely.
7. Properly secure power cord to strain relief.
8. Reinstall the cover.
3-wire Connection
Not for use in Canada.
DO NOT use for Mobile Home Installations.
NOT for use on new construction.
NOT for use on recreational vehicles.
NOT for use in areas where local codes prohibit 
grounding through the neutral conduction.
CONNECTING DRYER USING 4-WIRE 
CONNECTION (MUST BE USED FOR 
MOBILE HOME INSTALLATION)
NOTE: Since January 1, 1996, the National Electrical Code 
requires that new constructions use a 4-wire connection 
to an electric dryer. A 4-wire cord must also be used where 
local codes do not permit grounding through the neutral.
3-wire connection is NOT for use on new construction.
11
1. Turn off the circuit breaker(s) (30 amp) or remove the 
dryer’s circuit fuse at the electrical box.
2. Be sure the dryer cord is unplugged from the wall 
receptacle.
3. Remove the power cord cover located at the lower back.
4. Remove and discard ground strap. Keep the green 
ground screw for Step 7.
5. Install 3/4 in. UL-recognized strain relief to power cord 
entry hole. Bring power cord through strain relief. 
6. Connect power cord as follows:
  A. Connect the 2 hot lines to the outer screws of the 
terminal block (marked L1 and L2).
  B. Connect the neutral (white) line to the center of the 
terminal block (marked N).
7. Attach ground wire of power cord with the green 
ground screw (hole above strain relief bracket). Tighten 
all terminal block screws (3) securely.
8. Properly secure power cord to strain relief.
9. Reinstall the cover.
NEVER LEAVE THE COVER OFF OF THE TERMINAL 
BLOCK.
NEVER LEAVE THE COVER OFF OF THE TERMINAL 
BLOCK.
If required, by local code, install external ground (not 
provided) to grounded metal, cold water pipe, or other 
established ground determined by a qualified electrician.
Screws 
(2)
Remove ground strap 
and discard. Keep 
green ground screw
Hot 
Wire
Relocate 
green 
ground 
screw 
here
Green 
Wire
3/4” UL  
Recognized 
Strain Relief
4 #10 AWG minimum copper conductors or 120/240V 30A power supply 
cord kit marked for use with dryers and provided with closed loop or 
spade terminals with upturned ends (not supplied).
Hot 
Wire
Neutral 
(white)
Strain 
Relief 
Bracket
Cover
Screw
Screws 
(2)
Hot 
Wire
3/4” UL  
Recognized 
Strain Relief
3 #10 AWG minimum copper conductors or 120/240V 30A power supply 
cord kit marked for use with dryers and provided with closed loop or 
spade terminals with upturned ends (not supplied).
Hot 
Wire
Neutral 
(white)
Strain 
Relief 
Bracket
Cover
Screw
Green Ground Screw 
& Ground Strap