Installation Instructions
Installation Instructions
MOBILE OR MANUFACTURED 
HOME INSTALLATION
•  Installation MUST conform to the MANUFACTURED 
HOME CONSTRUCTION AND SAFETY 
STANDARD, TITLE 24, PART 3280 or STANDARD 
FOR MOBILE HOMES CAN/CSA-Z240 MH, or, 
when such standards are not applicable, with 
AMERICAN NATIONAL STANDARD FOR MOBILE 
HOME, ANSI/NFPA NO. 501B.
•  The dryer MUST be vented to the outdoors.
•  The exhaust vent MUST be securely fastened to a 
non-combustible portion of the mobile home.
•  The vent MUST NOT be terminated beneath a 
mobile or manufactured home.
•  The vent duct material MUST BE METAL.
•  KIT 14-D346-33 MUST be used to attach the dryer 
securely to the structure.
•  The vent MUST NOT be connected to any other 
duct, vent or chimney.
•  DO NOT use sheet metal screws or other 
fastening devices which extend into the interior of 
the exhaust vent.
•  Provide an opening with a free area of at least 25 
square inches for introduction of outside air into 
the dryer room.
•  See the sections for electrical connection information.
REQUIREMENTS FOR ALCOVE OR 
CLOSET INSTALLATION
Keep flammable materials and vapors, such as 
gasoline, away from dryer.
Place dryer at least 18” (46 cm) above the floor 
for a garage installation.
Failure to do so can result in death, explosion, or fire.
•  The dryer MUST be vented to the outdoors. 
•  Minimum clearance between dryer cabinet and 
adjacent walls or other surfaces is:
  0” either side
 0” rear
 0” front
 1” top
•  Consideration must be given to provide adequate 
clearance for installation and service.
•  Closet doors must be louvered or otherwise ventilated 
and have at least 60 square inches of open area. If 
the closet contains both a washer and a dryer, doors 
must contain a minimum of 120 square inches of 
open area.
NOTE: WHEN THE EXHAUST DUCT IS LOCATED AT 
THE REAR OF THE DRYER, THE CONFIGURATION 
OF THE DUCTING MAY REQUIRE GREATER THAN 
1” OF REAR CLEARANCE.
Gas Dryers Only:
•  No other fuel burning appliance shall be installed in 
the same closet as a gas dryer.
•  The dryer must be disconnected from the gas 
supply piping during pressure testing at pressures 
greater than ½ psi (3.5 kPa).
•  A 1/8 inch NPT minimum plugged tapping, 
accessible for test gauge connection, must be 
installed immediately upstream of the gas supply 
connection to the dryer.
- Explosion Hazard
WARNING
MINIMUM CLEARANCE OTHER THAN 
ALCOVE OR CLOSET INSTALLATION
Minimum clearance to combustible surfaces and 
for air opening are: 0” both sides, 0” rear and 1” top. 
Consideration must be given to provide adequate 
clearance for installation and service.
3