User Manual
Installation Instructions
Using exhaust longer than specified length will:
•  Increase the drying times and the energy cost.
•  Reduce the dryer life.
• 
Accumulate lint, creating a potential fire 
hazard.
The correct exhaust installation is YOUR 
RESPONSIBILITY.
Problems due to incorrect installation are not 
covered by the warranty.
The MAXIMUM ALLOWABLE length of the exhaust 
system depends upon the type of duct, number of 
turns, the type of exhaust hood (wall cap) and all 
conditions noted on the chart.
•  Internal elbows added for side or bottom vent 
conversions must be included in the total elbow 
count.
•  Any elbow greater than 45° should be treated as 
a 90° elbow.
•  Two 45° elbows will be treated like one 90° elbow.
•  For every additional 90° elbow, reduce the 
allowable vent system length by 10 feet.
•  When calculating the total vent system length, 
you must add all the straight portions and 
elbows of the system (including the transition 
duct).
EXHAUST LENGTH
13
4" DIA.
4"
4" DIA.
4" DIA.
2-1/2"
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types 
Recommended
No. of 90°
Elbows
Rigid
Metal
Rigid
Metal
120 Feet
100 Feet
85 Feet
70 Feet
60 Feet
90 Feet
75 Feet
65 Feet
55 Feet
45 Feet
0
1
2
3
4
55 Feet 35 Feet5
Use only for short
run installations
EXHAUST LENGTH
• DO  NOT bend 
or collapse 
ducting. Use 
elbows if turns 
are necessary.
• DO NOT use 
excessive 
exhaust 
length. Cut 
duct as short 
as possible.
• DO NOT 
crush duct 
against the 
wall
.
• DO NOT 
set dryer 
on duct
.
• DO cut duct as short 
as possible and install 
straight into wall.
•
 DO use elbows when 
turns are necessary.
Elbows