User Manual
• You must use with this dryer a flexible metal 
connector (listed connector ANSI Z21.24/CSA 6.10). 
The length of the connect shall not exceed 3 ft.
Installation Instructions
6
CONNECTING A GAS DRYER (skip for electric dryers) (cont.)
GAS REQUIREMENTS
DRYER GAS SUPPLY CONNECTION
GAS SUPPLY
•  A 1/8” National Pipe Taper thread plugged 
tapping, accessible for test gauge connection, 
must be installed immediately upstream of the 
gas supply connection to the dryer. Contact 
your local gas utility should you have questions 
on the installation of the plugged tapping.
•
  Supply line is to be 1/2” rigid pipe and equipped 
with an accessible shutoff within 6 feet of, and 
in the same room with, the dryer.
•
  Use pipe thread compound appropriate for 
natural or LP gas or use PTFE tape.
•
  Connect flexible metal connector to dryer and 
gas supply.
ADJUSTING FOR ELEVATION
•  Gas clothes dryers input ratings are based on 
sea level operation and need not be adjusted 
for operation at or below 2000 ft. elevation. For 
operation at elevations above 2000 ft., input 
ratings should be reduced at a rate of 4 percent 
for each 1000 ft. above sea level. 
•
  Installation must conform to local codes and 
ordinances or, in their absence, the NATIONAL 
FUEL GAS CODE, ANSI Z223.
- Explosion Hazard
WARNING
•   Use a new CSA International approved flexible 
gas supply line. Never reuse old flexible 
connectors.
• Install an individual manual shut-off valve 
within 6ft. of the dryer in accordance with the 
National Fuel Gas Code, ANSI Z223.1/NFPA 54.
• Securely tighten all gas connections.
• If connected to LP gas, have a qualified person 
make sure gas pressure DOES NOT exceed 13” 
water column.
• Examples of a qualified person include: licensed 
heating personnel, authorized gas company 
personnel, and authorized service personnel.
• Failure to do so can result in death, explosion, 
or fire.
1-7/8"
3-1/8"
3/8" NPT MALE THREAD GAS SUPPLY
NOTE: Add to vertical dimension
the distance between cabinet
bottom to floor.
• The installation must conform with local codes, 
or in the absence of local codes, with the 
National Fuel Gas Code, ANSI Z223.1/NFPA 54, 
or the Natural Gas and Propane Installation 
Code, CSA B149.1.
- Fire Hazard
WARNING
FOR USE WITH NATURAL GAS ONLY
Dryer as produced by manufacturer is to be used only 
with a natural gas supply. A manufacturer-supplied 
conversion kit is required to convert this dryer for 
propane gas supply. Use propane gas conversion 
kit WE25X217. Conversion must be made by properly 
trained and qualified personnel in accordance with 
local codes and ordinances.