Installation Guide

Installation Instructions
200mm & 300mm (Round signal)
Installation Steps:
1. Verify input voltage is within specified range on the back of the LED signal module before installation. Failure
to do so will cause lamp to fail.
2. Open front cover of (customer supplied) traffic signal housing.
3. Remove outer lens and incandescent bulb from traffic signal housing OR existing LED signal module. Retain all
hardware as removed as it may be needed in subsequent steps.
NOTE: Installer is responsible for ensuring the disposal of removed components complies with all applicable
regulatory requirements.
4. Ensure that a gasket is present around the perimeter of the new LED signal module.
5. Insert the LED signal module into the available cavity from previous LED module or incandescent bulb.
6. NOTE: Ensure that the arrow () on the back cover of the LED signal module is oriented pointing up.
7. Install mounting hardware to ensure that the LED signal module is securely fastened to traffic signal housing.
8. Connect the white wire to the neutral terminal block and the colored wire to the positive, supply voltage
terminal block.
9. NOTE: Ensure that the correct wire is securely connected to correct terminal block for proper operation.
10. After installation of all modules is complete, ensure all traffic signal housings are closed and secured properly.
11. Apply power and ensure proper operation of traffic signal modules per intersection requirements as specified
by customer.
…Page 2
Risk of Electric Shock
Install unit in enclosure tested
to be suitable for wet locations
only.
GTx Round Module 200mm
GTx Round Module 300mm
Voltage Rating
Up arrow ()
Prepare Electrical Wiring
Electrical Requirements
Do not use in wet locations
Follow all National Electric Codes
(NEC) and local codes.
WARNING / AVERTISSEMENT
Risk of Electric Shock. Disconnect Before Servicing or installing product.
Risque de choc électrique. Couper l’alimentation avant le dépannage ou avant
l’installation du produit.