GUD27ESSM/27GSSM
GE
®
Unitized Spacemaker
®
3.8 DOE Cu. Ft. Stainless Steel Washer and 5.9 Cu. Ft. Dryer
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
Specification Revised 11/17
GUV27 DRYER EXHAUST LENGTH
4" DIA.
4"
4" DIA.
4" DIA.
2-1/2"
RECOMMENDED MAXIMUM LENGTH
Exhaust HoodTypes
Recommended
No. of 90º
Elbows
Rigid
Metal
Rigid
Metal
200 Feet
185 Feet
175 Feet
165 Feet
155 Feet
145 Feet
175 Feet
165 Feet
155 Feet
145 Feet
135 Feet
125 Feet
0
1
2
3
4
5
Use only
for short
run installations
Special Installation Requirements
ALCOVE OR CLOSET INSTALLATION:
If your dryer is approved for installation in an alcove or closet, it will
be stated on a label on the dryer back.
– The dryer MUST be exhausted to the outside.
Minimum clearances between dryer cabinet and adjacent walls or
other surfaces are: 0" both sides and rear, 1" front and top
Minimum vertical space from floor to overhead cabinets, ceilings, etc.
is 76-1/2".
Closet doors must be louvered or otherwise ventilated and must
contain a minimum of 60 sq. in. of open area equally distributed. If
this closet contains both a washer and a dryer, doors must contain a
minimum of 120 sq. in. of open area equally distributed.
No other fuel-burning appliance shall be installed in the same close
with a gas dryer.
BATHROOM OR BEDROOM INSTALLATION:
– The dryer MUST be exhausted to the outdoors.
The installation must conform with the local codes, or in the absence
of local codes, with the National Electric Code and National Fuel Gas
Code, ANSI Z223 for gas dryers.
MINIMUM CLEARANCES OTHER THAN ALCOVE OR CLOSET
INSTALL ATION:
Minimum clearances to combustible surfaces:
0" both sides and rear
1" front and top