Quick Specs

Listed by
Underwriters
Laboratories
For answers to your Monogram, GE Café
Series, GE Profile
Series or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center
®
Service, 800.626.2000.
Specification Revised 11/17
GUV27ESSM
GE
®
Unitized Spacemaker
®
3.8 DOE Cu. Ft. Stainless Steel Washer
and 5.9 Cu. Ft. Long Vent Electric Dryer
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
For complete information, see installation instructions packed with your dryer.
DUCTING MATERIALS:
For best performance, this dryer should be vented with 4" diameter all rigid metal exhaust
duct. If rigid metal duct cannot be used, then UL-listed flexible metal (semi-rigid) ducting
can be used (Kit WX08X10077). In special installations, it may be necessary to connect the
dryer to the house vent using a flexible metal (foil-type) duct. A UL-listed flexible metal
(foil-type) duct may be used ONLY in installations where rigid metal or flexible metal (semi-
rigid) ducting cannot be used AND where a 4" diameter can be maintained throughout the
entire length of the transition duct. Please see installation instruction packed with your
dryer for complete instructions when using flexible metal (foil type) ducting.
EXHAUST LENGTH CALCULATION:
1. Determine the number of 90° turns needed for your installation. If you exhaust to the side
or bottom of dryer, add one turn.
2. The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated is
shown in the table.
For every extra 90° elbow, reduce the allowable vent system length by 10 ft. Two 45° elbows
will be treated like one 90° elbow. For the side exhaust installations, add one 90° elbow to
the chart. The total vent system length includes all the straight portions and elbows of the
system (transition duct included)..
Dryers must be exhausted to the outside.
CAUTION: For personal safety do not terminate exhaust into a chimney, under any
enclosed house floor (crawl space), or into an attic, since the accumulated lint could create
a fire hazard or moisture could cause damage. Never terminate the exhaust into a common
duct or plenum with a kitchen exhaust, since the combination of lint and grease could create
a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird
nesting, etc. The wall cap must also be located at least 12" above the ground or any other
obstruction with the opening pointed down.
GUV27 DRYER EXHAUST LENGTH
4" DIA.
4"
4" DIA.
4" DIA.
2-1/2"
RECOMMENDED MAXIMUM LENGTH
Exhaust HoodTypes
Recommended
No. of 90º
Elbows
Rigid
Metal
Rigid
Metal
200 Feet
185 Feet
175 Feet
165 Feet
155 Feet
145 Feet
175 Feet
165 Feet
155 Feet
145 Feet
135 Feet
125 Feet
0
1
2
3
4
5
Use only
for short
run installations