Specification

Performance Data for the Drinking Water Systems GXRQ18NBN and GNRQ18NBN
Models
Replacement
Element
Operating
Pressure
Range
Operating
Temperature
range
Recovery
Rating
Efficiency
Rating
Daily
Production
Rate (DPR)
GXRQ18NBN &
GNRQ18NBN
FQ18MN &
FQ18PN
40-100 psi
(275-689
kPa)
40-
100°F
(5-38°C) 21.18% 10.63%
14.76
gal/day
(55.9
liters/day)
Manufactured by: GE Appliances Louisville, KY 40225 800.432.2737
VOCs (by surrogate testing using
chloroform)
Drinking water
regualtory level
(MCL/MAC) ug/L
Influent/
Unfiltered
(g/L)
Effluent/
Filtered
(g/L)
Percent
Reduction
Alachlor
2.0
50
1.0
3
Atrazine
3.0
100
3.0
3
Benzene
5.0
81
1.0
3
99%
Carbofuran 40 190 1.0
3
>99%
Carbon Tetrachloride 5.0 78 1.8
4
98%
Chlorobenzene 100 77 1.0
3
99%
Chloropicrin NA 15 0.2
4
99%
2,4-D 70 110 1.7
4
98%
Dibromochloropropane (DBCP) 0.2 52 0.02
3
>99%
o-Dichlorobenzene 600 80 1.0
3
99%
p-Dichlorobenzene 75 40 1.0
3
98%
1,2-Dichloroethane 5.0 88 4.8
5
95
5%
1,1-Dichloroethylene 7.0 83 1.0
3
99%
cis-1,2-Dichloroethylene 70 170 0.5
3
>99%
trans-1,2-Dichloroethylene 100 86 1.0
3
99%
1,2-Dichloropropane 5.0 80 1.0
3
99%
cis-1,3-Dichloropropylene NA 79 1.0
3
99%
Dinoseb 7.0 170 0.2
4
99%
Endrin 2.0 53 0.59
4
99%
Ethylbenzene 700 88 1.0
3
99%
Ethylene Dibromide (EDB) 0.05 44 0.02
3
>99%
Haloacetonitriles (HAN): NA
Bromochloroacetonitrile NA 22 0.5
4
98%
Dibromoacetonitrile NA 24 0.6
4
98%
Dichloroacetonitrile NA 9.6 0.2
4
98%
Trichloroacetonitrile NA 15 0.3
4
98%
Haloketones (HK):
NA
1,1
-
dichloro
-
2
-
propanone
NA
7.2
0.1
4
99%
1,1,1
-
trichloro
-
2
-
propanone
NA
8.2
6
0.3
4
96%
Heptachlor
0.4
25
0.01
3
Heptachlor Epoxide
0.2
10.7
6
0.2
6
98%
Hexachlorobutadiene NA 44 1.0
3
98%
Hexachlorocyclopentadiene 50 60 0.002
3
>99%
Lindane 0.2 55 0.01
3
>99%
Methoxychlor 40 50 0.1
3
>99%
Pentachlorophenol 1.0 96 1.0
3
99%
Simazine 4.0 120 4.0
3
97%
Styrene 100 150 0.5
3
>99%
1,1,2,2-Tetrachloroethane NA 81 1.0
3
99%
Tetrachloroethylene 5.0 81 1.0
3
99%
Toluene 1,000 78 1.0
3
99%
2,4,5-TP (silvex) 50 270 1.6
3
99%
Tribromoacetic acid NA 42 1.0
3
98%
1,2,4-Trichlorobenzene 70 160 0.5
3
>99%
1,1,1-Trichloroethane 200 84 4.6
4
95%
1,1,2-Trichloroethane 5.0 150 0.5
3
>99%
Trichloroethylene 5.0 180 1.0
3
>99%
Chloroform (THM) 80 300 15 95%
Bromoform (THM)
Bromodichloromethane (THM)
Chlorodibromomethane (THM)
Xylenes (total) 10,000 70 1.0
3
99%
NSF/ ANSI 42
Minimum
Reduction
Overall %
Reduction Results
Chlorine Taste and Odor <0.5 mg/L 97.5 Pass
NSF P473
Influent
challenge
concentration
Maximum
permissible
concentration
Overall %
Reduction Results
Perfluorooctanoic
acid (PFOA) &
Perfluoroctane
sulfonate (PFOS) 1.510% ug/L 0.07 ug/L 97.4% Pass
NSF/ANSI 53
Influent Challenge
concentration
Maximum
permissible
concentration
Overall %
Reduction Results
VOC Surrogate
Test 300 ug/L 99.8% 99.8 Pass
MTBE 5ug/L 97.8% 97.8 Pass
Filter Performance Data
Flow Rate 0.8 gallons per minute (3.03 liters per minute)
Capacity 240 gallons (908 Liters)
1
Tested by Spectrum Labs, a qualified independent laboratory, against accepted industry
protocol.
Testing was performed under standard laboratory conditions, actual performance may vary.
This system has been tested according to NSF/ANSI 58 for the reduction of substances listed
above. The concentration of the indicated substances was reduced to a concentration less
than or equal to the permissible limit for water leaving the system as specified in standards
53, 58,401 and Protocol P473.
Efficiency rating means the percentage of the influent water to the system that is available to
the user as reverse osmosis treated water under operating conditions that approximate
typical daily usage.
Recovery rating means the percentage of the influent water to the membrane portion of the
system that is available to the user as reverse osmosis treated water when the system is
operated without a storage tank or when the storage tank is bypassed.
Do not use with water that is microbiologically Insafe or of unknown quality without adequate
disinfection before or after the system. This system is certified for cyst reduction and may
be used on disinfected water that may contain filterable cysts.
This system is acceptable for treatment of influent concentrations of no more than 27mg/L
nitrate and 3 mg/L nitrite in combination measured as N and is certified for nitrate/nitrite
reduction only for water supplies with a pressure of 40 psig (276 kPa) or greater.
This system has been tested for the treatment of water containing pentavalent arsenic (also
known as As (V), As (+5), or arsenate) at concentrations of 0.30 mg/L or less. This system
reduces pentavalent arsenic, but may not reduce other forms of arsenic. This system shall
be used on water supplies containing a detectable free chlorine residual at the system inlet
or on water supplies that have been demonstrated to contain only pentavalent arsenic.
Treatment with chloramine (combined chlorine) is not sufficient to ensure complete
conversion of trivalent arsenic to pentavalent arsenic. Please see the Arsenic Facts section
of the Performance Data Sheet for further information.
4/2/19 (Rev. D)
7376046