Installation

Placetheunitonaplatformortableevenwiththecutoutopening.Theplatformmustsupport200lbs.(91kg).
Connecttheflexibleconduittotheelectricaljunctionboxasfollows:
THREE-CONDUCTOR BRANCH CIRCUIT CONNECTION
NOTE:Ifresidenceleadsorgroundarealuminumconductors,seeWARNINGinsection5A,Electrical
Requirements.
Whenconnectingtoathree-conductorbranchcircuit,iflocalcodespermit:
FOUR-CONDUCTOR BRANCH CIRCUIT CONNECTION
NOTE:Ifresidenceleadsorgroundarealuminumconductors,seeWARNINGinsection5A,Electrical
Requirements.
Whenconnectingtoafour-conductorbranchcircuit,iflocalcodespermit:
1.
Connectthebareovengroundconductorwiththe
crimpedneutral(white)leadtothebranchcircuit
neutral(whiteorgrayincolor),usingwirenuts.
2.
Connecttheovenredleadtothebranchcircuitred
lead,andtheovenblackleadtothebranchcircuit
blackleadinaccordancewithlocalcodes,using
wirenuts.
3.
Installproperstrainreliefclamp.
4.
Installjunctionboxcover.
1.
Cuttheneutral(white)leadfromtheclamp.Re-strip
theneutral(white)leadtoexposetheproperlength
ofconductor.
2.
Attachtheappliancegroundinglead(greenorbare
copper)inaccordancewithlocalcodes.
3.
Connecttheovenneutral(white)leadtothebranch
circuitneutral(whiteorgray)inaccordancewith
localcodes,usingawirenut.
4.
Connecttheovenredleadtothebranchcircuitred
leadandtheovenblackleadtothebranchcircuit
blackleadinaccordancewithlocalcodes,using
wirenuts.
5.
Installproperstrainreliefclamp.
6.
Installjunctionboxcover.
Branch
circuit
Black
Alternate
knockout
Neutralbarewire
connection
Rangeconduit
snapsintobox
Red
Groundand
neutralwires
(white)
Branch
circuit
Black
Alternate
knockout
Rangeconduit
snapsintobox
Red
White
Ground
wires
6
InstallationInstructions
5B
MAKE ELECTRICAL CONNECTIONS