Specification

JD630ST/DT
GE
®
30" Drop-In Electric Range
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
ADA
COMPLIANT
All GE Appliances ranges are equipped
with an Anti-Tip device. The installation
of this device is an important, required
step in the installation of the range.
Listed by
Underwriters
Laboratories
For answers to your Monogram, GE Café
, GE Profile
or
GE Appliances product questions, visit our website at
geappliances.com or call GE Answer Center
®
Service at 800.626.2000.
Specification Revised 5/22
JUNCTION BOX LOCATION: Electric drop-ins are not approved for
installation with a plug and receptacle. This range is supplied with a
flexible conduit and must be hard wired to a junction box. See shaded
area in drawing for location of junction box. Refer to installation
instructions for more information.
IMPORTANT: 30" DROP-IN RANGES ARE DESIGNED TO HANG
FROM THE COUNTERTOP. IT DOES NOT REST ON THE FLOOR.
FOR INSTALLATION ALTERNATIVES, REFER TO INSTALLATION
INSTRUCTIONS.
NOTE: This appliance has been approved for 0" spacing to adjacent
surfaces above the cooktop. However, a 6" minimum spacing to
surfaces less than 15" above the cooktop and adjacent cabinet is
recommended to reduce exposure to steam, grease splatter and heat.
INSTALLATION INFORMATION:
Before installing, consult installation instructions
for current dimensional data and additional
requirements.
NOTE: Check local codes for required breaker size.
KW RATING
240V 11.9
208V 8.9
BREAKER SIZE
240V 40 Amps
208V 40 Amps
Acceptable Electrical Outlet
Area Also In Adjacent
Cabinet Or Under Floor
Conduit is 40" long
30" Min.
30" Min.
15" Min.
Recommended
6" Min.
from walls
2-7/8"
To Front Surface
of Countertop
30"
27-1/2"
25"
23-3/16"
If necessary,
build up sides
to 1-1/4" thick
to provide
countertop
support
27"
20-5/8" Door
Clearance
From Front
Surface of
Countertop
24"
31-1/4"
25-3/4"*
(excluding handle)
*Total depth from wall to
front of closed oven door
including handle is 28-1/2"
28-1/2"
23-3/16"
30"
30"
If you are NOT using the filler strip:
If you are using the filler strip:
25"
DROP-IN ELECTRIC RANGE
Acceptable Electrical Outlet
Area Also In Adjacent
Cabinet Or Under Floor
Conduit is 40" long
30" Min.
30" Min.
15" Min.
Recommended
6" Min.
from walls
2-7/8"
To Front Surface
of Countertop
30"
27-1/2"
25"
23-3/16"
If necessary,
build up sides
to 1-1/4" thick
to provide
countertop
support
27"
20-5/8" Door
Clearance
From Front
Surface of
Countertop
24"
31-1/4"
25-3/4"*
(excluding handle)
*Total depth from wall to
front of closed oven door
including handle is 28-1/2"
28-1/2"
23-3/16"
30"
30"
If you are NOT using the filler strip:
If you are using the filler strip:
25"
DROP-IN ELECTRIC RANGE
Dimension and installation information are shown in inches.
Above illustration intended for dimensional reference only.
Refer to photograph for actual product appearance.

Summary of content (2 pages)