Specification
JD630ST/DT
GE
®
30" Drop-In Electric Range
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
ADA
COMPLIANT
All GE Appliances ranges are equipped
with an Anti-Tip device. The installation
of this device is an important, required
step in the installation of the range.
Listed by
Underwriters
Laboratories
For answers to your Monogram, GE Café
™
, GE Profile
™
or
GE Appliances product questions, visit our website at
geappliances.com or call GE Answer Center
®
Service at 800.626.2000.
Specification Revised 5/22
JUNCTION BOX LOCATION: Electric drop-ins are not approved for
installation with a plug and receptacle. This range is supplied with a
flexible conduit and must be hard wired to a junction box. See shaded
area in drawing for location of junction box. Refer to installation
instructions for more information.
IMPORTANT: 30" DROP-IN RANGES ARE DESIGNED TO HANG
FROM THE COUNTERTOP. IT DOES NOT REST ON THE FLOOR.
FOR INSTALLATION ALTERNATIVES, REFER TO INSTALLATION
INSTRUCTIONS.
NOTE: This appliance has been approved for 0" spacing to adjacent
surfaces above the cooktop. However, a 6" minimum spacing to
surfaces less than 15" above the cooktop and adjacent cabinet is
recommended to reduce exposure to steam, grease splatter and heat.
INSTALLATION INFORMATION:
Before installing, consult installation instructions
for current dimensional data and additional
requirements.
†
NOTE: Check local codes for required breaker size.
KW RATING
240V 11.9
208V 8.9
BREAKER SIZE
240V 40 Amps
†
208V 40 Amps
†
Acceptable Electrical Outlet
Area Also In Adjacent
Cabinet Or Under Floor
Conduit is 40" long
30" Min.
30" Min.
15" Min.
Recommended
6" Min.
from walls
2-7/8"
To Front Surface
of Countertop
30"
27-1/2"
25"
23-3/16"
If necessary,
build up sides
to 1-1/4" thick
to provide
countertop
support
27"
20-5/8" Door
Clearance
From Front
Surface of
Countertop
24"
31-1/4"
25-3/4"*
(excluding handle)
*Total depth from wall to
front of closed oven door
including handle is 28-1/2"
28-1/2"
23-3/16"
30"
30"
If you are NOT using the filler strip:
If you are using the filler strip:
25"
DROP-IN ELECTRIC RANGE
Acceptable Electrical Outlet
Area Also In Adjacent
Cabinet Or Under Floor
Conduit is 40" long
30" Min.
30" Min.
15" Min.
Recommended
6" Min.
from walls
2-7/8"
To Front Surface
of Countertop
30"
27-1/2"
25"
23-3/16"
If necessary,
build up sides
to 1-1/4" thick
to provide
countertop
support
27"
20-5/8" Door
Clearance
From Front
Surface of
Countertop
24"
31-1/4"
25-3/4"*
(excluding handle)
*Total depth from wall to
front of closed oven door
including handle is 28-1/2"
28-1/2"
23-3/16"
30"
30"
If you are NOT using the filler strip:
If you are using the filler strip:
25"
DROP-IN ELECTRIC RANGE
Dimension and installation information are shown in inches.
Above illustration intended for dimensional reference only.
Refer to photograph for actual product appearance.