Installation Guide

CAUTION
To prevent
drafts from affecting burner
operation, seal all openings
in floor under appliance and
behind appliance wall.
18”
Minimum
to cabinets
above counter
0”
Minimum
to cabinets
below
cooktop
30”
Minimum
30”
15”
Max to
cabinets
above
counter
3” Right side
6” Left side
Minimum
to side wall
36”
30”
2”
5”
4”
9”
13”
14 1/2”
24”
4 1/2”
12 1/2”
Side Wall
Gas
and
electrical
supply
DIMENSIONS AND CLEARANCES
Provide adequate clearances
between the range and adjacent
combustible surfaces. These
dimensions must be met for safe
use of your range.
Allow 30” (76.2 cm) minimum
clearance between burners and
bottom of unprotected wood or
metal cabinet, or allow a 24” (61
cm) minimum when bottom of wood
or metal cabinet is protected by
no less than 1/4” (6.4 mm) thick
flame-retardant millboard covered
with no less than No. 28 MSG sheet
metal (.015” [.38 mm] thick), .015”
(.38 mm) thick stainless steel, .025”
(0.64 mm) aluminum or .020” (0.5
mm) copper.
Installation of a listed microwave
oven or cooking appliance over
the cooktop shall conform to the
installation instructions packed with
that appliance.
For island installation, maintain
2-1/2” minimum from cutout to
back edge of countertop and 3”
minimum from cutout to side edges
of countertop.
GAS PIPE AND ELECTRICAL OUTLET LOCATIONS
CONVERTING TO PROPANE
GAS (OR CONVERTING
BACK TO NATURAL GAS
FROM PROPANE)
This range leaves the factory set for use with
natural gas. If you want to convert to propane
gas, the conversion must be performed by a
qualified propane gas installer.
The conversion orifices and instructions can
be found on back of the range.
Keep these instructions and all orifices in case
you want to convert back to natural gas.
INSTALLATION AT HIGH ALTITUDE
Over 6000ft, product configured for natural gas or propane requires installation of kit
(WB28X29254 for natural gas and WB28X29255 for propane gas). Follow the instructions
included with the kit.
Rear of Range
Orifice Box
(location
may vary)
Minimum to
cabinets on
either side
of the range.
Minimum
clearance
to left wall
Minimum
Minimum
clearance to
right wall
Maximum
depth for
cabinets above
countertops
Front edge of
the range side
panel forward
from cabinet
To cabinets below cooktop
and at the range back
To cabinets
below
cooktop and
at the range
back
18"
3"
30"
30"
13"
6"
36"
0"
0"
1/4"
GAS PIPE AND ELECTRICAL
OUTLET LOCATIONS
SINGLE OVEN GAS RANGE
Recommended area for 120V
outlet on rear wall and area for
through-the-wall conection of
pipe stub and shut-off valve.
Recommended area
for through-the-floor
connection of pipe stub
and shut-off valve.
4 1/2"
4"
2"
8"
5"
3"
14 1/2"
9"
30"
46 1/4"
28 3/4"
w/ handle
26 1/4"
w/o handle
30"
36 1/4" ± 1/4"
11 1/4"
AB DEFGHC
30" 10 1/4" 46 1-4" 36 1/4" 28 3/4" 3" 6"26 1/4"