Quick Specs

JGBS30DEK/REK
GE
®
Series 30" Free-Standing Gas Range
All GE ranges are equipped
with an Anti-Tip device.
The installation of this
device is an important,
required step in the
installation of the range.
DIMENSIONS AND INSTALLATION INFORMATION
Specification Revised 9/17
For answers to your Monogram, GE Café
Series, GE Profile
Series or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center
®
Service, 800.626.2000.
ELECTRICAL RATING: 120V, 60Hz, 15A
INSTALL ATION INFORMATION: Before installing,
consult installation instructions packed with
product for current dimensional data.
Minimum to
cabinets on
either side
of the range.
Minimum
clearance
to left wall
Minimum
Minimum
clearance to
right wall
Maximum
depth for
cabinets above
countertops
To cabinets below cooktop
and at the range back
To cabinets
below
cooktop and
at the range
back
18"
2"
30"
30"
13"
2"
36"
0"
Front edge of
the range side
panel forward
from cabinet
0"
1/4"
GAS PIPE AND ELECTRICAL
OUTLET LOCATIONS
SINGLE OVEN GAS RANGE
Recommended area for 120V
outlet on rear wall and area for
through-the-wall conection of
pipe stub and shut-off valve.
Recommended area
for through-the-floor
connection of pipe stub
and shut-off valve.
4 1/2"
4"
2"
8"
5"
3"
14 1/2"
9"
30"
30"
46 1/4"
28 3/4"
w/ handle
26 1/4"
w/o handle
10 1/4"
36"
to
36 1/4"
Minimum to
cabinets on
either side
of the range.
Minimum
clearance
to left wall
Minimum
Minimum
clearance to
right wall
Maximum
depth for
cabinets above
countertops
To cabinets below cooktop
and at the range back
To cabinets
below
cooktop and
at the range
back
18"
2"
30"
30"
13"
2"
36"
0"
Front edge of
the range side
panel forward
from cabinet
0"
1/4"
GAS PIPE AND ELECTRICAL
OUTLET LOCATIONS
SINGLE OVEN GAS RANGE
Recommended area for 120V
outlet on rear wall and area for
through-the-wall conection of
pipe stub and shut-off valve.
Recommended area
for through-the-floor
connection of pipe stub
and shut-off valve.
4 1/2"
4"
2"
8"
5"
3"
14 1/2"
9"
30"
30"
46 1/4"
28 3/4"
w/ handle
26 1/4"
w/o handle
10 1/4"
36"
to
36 1/4"
Minimum to
cabinets on
either side
of the range.
Minimum
clearance
to left wall
Minimum
Minimum
clearance to
right wall
Maximum
depth for
cabinets above
countertops
To cabinets below cooktop
and at the range back
To cabinets
below
cooktop and
at the range
back
18"
2"
30"
30"
13"
2"
36"
0"
Front edge of
the range side
panel forward
from cabinet
0"
1/4"
GAS PIPE AND ELECTRICAL
OUTLET LOCATIONS
SINGLE OVEN GAS RANGE
Recommended area for 120V
outlet on rear wall and area for
through-the-wall conection of
pipe stub and shut-off valve.
Recommended area
for through-the-floor
connection of pipe stub
and shut-off valve.
4 1/2"
4"
2"
8"
5"
3"
14 1/2"
9"
30"
30"
46 1/4"
28 3/4"
w/ handle
26 1/4"
w/o handle
10 1/4"
36"
to
36 1/4"

Summary of content (2 pages)