LP Conversion

Propane Conversion Kit
LP
CONVERSION
KIT
BURNER OUTPUT RATINGS: BTU/HR
Propane Gas 10” W.C.P.
BURNER
BTU
RATE
ORIFICE
SIZE (mm) COLOR MARKING
RF 11,000 0.039” (0.99) Blue/Magenta 99L
LF 9,500 0.035” (0.89) Blue/Brown 89L
RR 5,000 0.026” (0.66) Red/Yellow 66L
LR 9,500 0.035” (0.89) Blue/Brown 89L
OVEN 16,000 0.048” (1.21) Pink 0.048
To adjust your range for use with propane gas, follow these
instructions:
1. Disconnect all electrical power, at the main circuit breaker or
fuse box.
2. Shut off the gas supply to the range by closing the manual
shut-off valve.
CONVERTING THE PRESSURE REGULATOR
CONVERTING THE COOKTOP BURNERS
A. Remove the top grates, burner caps and burner heads.
B. Using a 7 mm or 9/32” nut driver, remove the top burner
RUL¿FHV7KHVHPD\EHDFFHVVHGWKURXJKWKHEXUQHU
opening in the base.
&5HPRYHWKHSURSDQHRUL¿FHVIURPWKHER[SURYLGHG7KH
SURSDQHRUL¿FHVKDYHWKHOHWWHU³/´RQWKHWRS
To aid in identifying the proper location for the propane
RUL¿FHVGXULQJFRQYHUVLRQIURP1DWXUDO*DVWR3URSDQH
*DVFRORUFRGHVKDYHEHHQDGGHGWRWKHVLGHRUWRSRIWKH
RUL¿FH6HHWKHFKDUWEHORZ(DFKRUL¿FHPD\DOVRVKRZD
series of engraved marks (I, II, III . . .) located on the top.
The pressure regulator is located on the rear of the range.
(Some models will have a metal shield protecting the regulator
that must be removed for conversion and reinstalled when
conversion is complete.) The pressure regulator is located in the
lower, left hand side of the range as viewed from the front left.
A. If this is your regulator:
1. Use an adjustable wrench to unscrew the hex-nut cap
from the pressure regulator.
2. Completely remove the protective plastic cap off the
threaded metal cap.
3. Turn the metal cap so the type of gas being converted to
is displayed and replace the protective plastic cover.
4. Screw the hex-nut cap back into the regulator.
(Do not over tighten)
B. If this is your regulator:
1. Use an adjustable wrench to unscrew the hex-nut cap
from the pressure regulator.
2. Turn the plastic cap 1/4 turn to disassemble.
3. Turn the plastic cap over and hook it into the slots.
Rotate cap 1/4 turn to reassemble. The type of gas to be
used should now be visible on the top of the cap.
4. Screw the hex-nut cap back onto the pressure regulator.
TOOLS REQUIRED:
• Adjustable wrench
• 1/2” Open-end wrench
• Phillips head screwdriver
• Flat bladed screwdriver
(blade approximately
3/32” across)
• Nut drivers: 1/4”, 9/32”
or 7mm
Pressure Regulator *DV9DOYH
PROPANE CONVERSION INSTRUCTIONS
PROPANE
NAT
Rotate cap counter-
clockwise to loosen
Cap assembly
Regulator style A
Rotate cap counter-
clockwise to loosen.
PROPANE
NAT
Regulator style B
WARNING
Explosion Hazard
Death or serious injury can result from failure to follow
these instructions.
Service by a qualified service technician only.
Shut off gas supply and disconnect power before servicing.
Reconnect all grounding devices after service.
Replace all parts and panels before operating.
NOTICE:
If you are using propane (bottled) gas, all adjustments
described in the following steps must be made before you
make any burner adjustments.
NOTICE:
6DYHWKHVHRUL¿FHVIRUIXWXUHFRQYHUVLRQEDFNWRQDWXUDOJDV
WARNING
Do not operate the cooktop or oven
burners of this range when using propane (bottled) gas
EHIRUHFRQYHUWLQJWKHSUHVVXUHUHJXODWRUDQGEXUQHURUL¿FHV
for propane gas use. Failure to do so could cause high
ÀDPHVDQGWR[LFIXPHVZKLFKFDQUHVXOWLQVHULRXVLQMXU\
7KHSUHVVXUHUHJXODWRUDQGWKHEXUQHURUL¿FHVDUHVHWIRU
natural gas. To use propane gas, the regulator and burner
RUL¿FHVPXVWEHFRQYHUWHG
7KHSURSDQHRUL¿FHVIRUWKHFRRNWRSEXUQHUVDUHVKLSSHGRQ
the back of the range in a small box.
',QVWDOOWKHSURSDQHRUL¿FHVLQWKHLUSUHFLVHORFDWLRQV
7RSUHYHQWOHDNDJHPDNHVXUHWKHRUL¿FHVSXGVDUHVHFXUHO\
screwed into the gas supply tubes.
(,QVWDOOWKHROGRUL¿FHVSXGVLQWRWKHPHWDOER[RUEUDFNHW
along with these instructions, and replace onto the back of the
range for possible future conversion.
95
III
Denotes 0.95mm Orifice size opening
Denotes LP (Propane)
Burner
cap
Burner construction
Burner
head
Base
Orifice
located
through this
opening
LR
RR
LF RF
Blue/Magenta
Propane
Blue/Brown
Propane
Blue/Brown
Propane
Red/Yellow
Propane
PROPANE CONVERSION INSTRUCTIONS