LP Conversion Kit
BURNER OUTPUT RATINGS: BTU/HR
Propane (LP) Gas 10” W.C.P.
BURNER
BTU
RATE
ORIFICE
SIZE (mm) COLOR MARKING
RF 12,000 0.039” (0.99) Blue/Magenta 99L
LF 9,500 0.035” (0.89) Blue/Brown 89L
RR 5,000 0.026” (0.66) Red/Yellow 66L
LR 9,500 0.035” (0.89) Blue/Brown 89L
OVEN 16,000 0.048” (1.21) Pink 0.048
To adjust your range for use with propane (LP) gas, follow
these instructions:
1. Disconnect all electrical power, at the main circuit breaker or
fuse box.
2. Shut o the gas supply to the range by closing the manual
shut-o valve.
CONVERTING THE PRESSURE REGULATOR
CONVERTING THE COOKTOP BURNERS
A. Remove the top grates, burner caps and burner heads.
B. Using a 7 mm or 9/32” nut driver, remove the top burner
orices. These may be accessed through the burner
opening in the base.
C. Remove the propane (LP) orices from the box provided.
The propane (LP) orices have the letter “L” on the top.
To aid in identifying the proper location for the propane (LP)
orices during conversion from Natural Gas to Propane
(LP) Gas, color codes have been added to the side or top of
the orice. See the chart below. Each orice may also show
a series of engraved marks (I, II, III . . .) located on the top.
The pressure regulator is located on the rear of the range.
(Some models will have a metal shield protecting the regulator
that must be removed for conversion and reinstalled when
conversion is complete.) The pressure regulator is located in the
lower, left hand side of the range as viewed from the front left.
1. Use an adjustable wrench to unscrew the hex-nut cap from
the pressure regulator.
2. Completely remove the protective plastic cap o the
threaded metal cap.
3. Turn the metal cap so the type of gas being converted to is
displayed and replace the protective plastic cover.
4. Screw the hex-nut cap back into the regulator.
(Do not over tighten)
TOOLS REQUIRED:
• Adjustable wrench
• 1/2” Open-end wrench
• Phillips head screwdriver
• Flat bladed screwdriver
(blade approximately
3/32” across)
• Nut drivers: 1/4”, 9/32”
or 7mm
Pressure Regulator Gas Valve
PROPANE (LP) CONVERSION INSTRUCTIONS
PROPANE
NAT
Rotate cap counter-
clockwise to loosen
Cap assembly
WARNING
Explosion Hazard
Death or serious injury can result from failure to follow
these instructions.
• Service by a qualified service technician only.
• Shut off gas supply and disconnect power before servicing.
• Reconnect all grounding devices after service.
• Replace all parts and panels before operating.
NOTICE:
If you are using propane (LP) (bottled) gas, all
adjustments described in the following steps must be
made before you make any burner adjustments.
NOTICE:
Save these orices for future conversion back to natural gas.
WARNING
Do not operate the cooktop or oven
burners of this range when using propane (LP) (bottled) gas
before converting the pressure regulator and burner orices
for propane (LP) gas use. Failure to do so could cause high
ames and toxic fumes which can result in serious injury.
The pressure regulator and the burner orices are set for
natural gas. To use propane (LP) gas, the regulator and burner
orices must be converted.
D. Install the propane (LP) orices in their precise locations.
To prevent leakage, make sure the orice spuds are securely
screwed into the gas supply tubes.
E. Install the old orice spuds into the metal box or bracket
along with these instructions, and replace onto the back of the
range for possible future conversion.
95
III
Denotes 0.95mm Orifice size opening
Denotes LP (Propane)
Burner
cap
Burner construction
Burner
head
Base
Orifice
located
through this
opening
LR
RR
LF RF
Blue/Magenta
Propane
Blue/Brown
Propane
Blue/Brown
Propane
Red/Yellow
Propane
PROPANE (LP) CONVERSION INSTRUCTIONS
31-2000947 Rev. 0 07-21 GEA
JGBS10, JGBS30, JGBS61, RGBS300, RGBS400, JGBS60, RGBS330 and XGBS400
The propane orices for the cooktop burners are shipped on
the back of the range in the location shown.
Propane Conversion Kit