LP Conversion

Propane Conversion Kit
LP
CONVERSION
KIT
BURNER OUTPUT RATINGS: BTU/HR
Propane Gas 10” W.C.P.
BURNER
BTU
RATE
ORIFICE
SIZE (mm) COLOR MARKING
RF 9,500 0.035” (0.89) Blue/Brown 89L
LF 15,000 0.045” (1.14) Orange/Yellow 114L
RR 12,000 0.039” (0.99) Blue/Magenta 99L
LR 5,000 0.026” (0.66) Red/Yellow 66L
OVEN 16,000 0.048” (1.21) Pink .048
To adjust your range for use with propane gas, follow these
instructions:
1. Disconnect all electrical power, at the main circuit breaker or
fuse box.
2. Shut off the gas supply to the range by closing the manual
shut-off valve.
CONVERTING THE PRESSURE REGULATOR
CONVERTING THE COOKTOP BURNERS
A. Remove the top grates, burner caps and burner heads.
B. Using a 7 mm or 9/32” nut driver, remove the top burner
orifices. These may be accessed through the burner
opening in the base.
C. Remove the propane orifices from the box provided. The
propane orifices have the letter “L” on the top.
To aid in identifying the proper location for the propane
orifices during conversion from Natural Gas to Propane
Gas, color codes have been added to the side or top of the
orifice. See the chart below. Each orifice may also show a
series of engraved marks (I, II, III . . .) located on the top.
The pressure regulator is located on the rear of the range.
(Some models will have a metal shield protecting the regulator
that must be removed for conversion and reinstalled when
conversion is complete.) The pressure regulator is located in the
lower, left hand side of the range as viewed from the front left.
A. If this is your regulator:
1. Use an adjustable wrench to unscrew the hex-nut cap
from the pressure regulator.
2. Completely remove the protective plastic cap off the
threaded metal cap.
3. Turn the metal cap so the type of gas being converted to
is displayed and replace the protective plastic cover.
4. Screw the hex-nut cap back into the regulator.
(Do not over tighten)
B. If this is your regulator:
1. Use an adjustable wrench to unscrew the hex-nut cap
from the pressure regulator.
2. Turn the plastic cap 1/4 turn to disassemble.
3. Turn the plastic cap over and hook it into the slots.
Rotate cap 1/4 turn to reassemble. The type of gas to be
used should now be visible on the top of the cap.
4. Screw the hex-nut cap back onto the pressure regulator.
TOOLS REQUIRED:
• Adjustable wrench
• 1/2” Open-end wrench
• Phillips head screwdriver
• Flat bladed screwdriver
(blade approximately
3/32” across)
• Nut drivers: 1/4”, 9/32”
or 7mm
Pressure Regulator Gas Valve
PROPANE CONVERSION INSTRUCTIONS
PROPANE
NAT
Rotate cap counter-
clockwise to loosen
Cap assembly
Regulator style A
Rotate cap counter-
clockwise to loosen.
PROPANE
NAT
Regulator style B
WARNING
Explosion Hazard
Death or serious injury can result from failure to follow
these instructions.
Service by a qualified service technician only.
Shut off gas supply and disconnect power before servicing.
Reconnect all grounding devices after service.
Replace all parts and panels before operating.
NOTICE:
If you are using propane (bottled) gas, all adjustments
described in the following steps must be made before you
make any burner adjustments.
NOTICE:
Save these orifices for future conversion back to natural gas.
WARNING
Do not operate the cooktop or oven
burners of this range when using propane (bottled) gas
before converting the pressure regulator and burner orifices
for propane gas use. Failure to do so could cause high
flames and toxic fumes which can result in serious injury.
The pressure regulator and the burner orifices are set for
natural gas. To use propane gas, the regulator and burner
orifices must be converted.
The propane orifices for the cooktop burners are shipped on
the back of the range in a small box.
D. Install the propane orifices in their precise locations.
To prevent leakage, make sure the orifice spuds are securely
screwed into the gas supply tubes.
E. Install the old orifice spuds into the metal box or bracket
along with these instructions, and replace onto the back of
the range for possible future conversion.
95
III
Denotes 0.95mm Orifice size opening
Denotes LP (Propane)
Burner
cap
Burner construction
Burner
head
Base
Orifice
located
through this
opening
PROPANE CONVERSION INSTRUCTIONS
31-11121 06-17 GEA
JGBS62
LR
RR
LF RF
Blue/Brown
Propane
Orange/Yellow
Propane
Red/Yellow
Propane
Blue/Magenta
Propane
Printed in Mexico

Summary of content (2 pages)