Installation Instructions
ELECTRICAL CONNECTION 
INFORMATION FOR ELECTRIC 
DRYERS
Use a new UL-listed 240V 30 amp dryer power 
supply cord with closed ring terminals or spade 
terminals with upturned ends.
Use a UL-listed strain relief.
Disconnect power before making electrical 
connections. 
Connect neutral wire (white or center wire) to center 
terminal.
Ground wire (green or bare wire) must be connected 
to green ground connector. 
Connect remaining two supply wires to remaining 
two terminals.
Securely tighten all electrical connections.
Replace the terminal block cover.
Failure to do so can result in death, fire or electrical 
shock.
For electrical connections using a 
power cord:
ELECTRICAL CONNECTION 
INFORMATION FOR ELECTRIC 
DRYERS
For direct wire connections:
Use 10 gauge solid copper wire.
Use a UL-listed strain relief.
Disconnect power before making electrical 
connections. 
Connect neutral wire (white or center wire) to center 
terminal.
Ground wire (green or bare wire) must be connected 
to green ground connector. 
Connect remaining two supply wires to remaining 
two terminals.
Securely tighten all electrical connections.
Replace the terminal block cover.
Failure to do so can result in death, fire or electrical 
shock.
GROUNDING INSTRUCTIONS
For a grounded, cord-connected dryer: This 
dryer must be grounded. In the event of a 
malfunction or breakdown, grounding will 
reduce the risk of electric shock by providing 
a path of least resistance for electric current. 
This dryer uses a cord having an equipment-
grounding conductor and a grounding plug. 
The plug must be plugged into an appropriate 
outlet that is properly installed and grounded in 
accordance with all local codes and ordinances.
Improper connection of the 
equipment-grounding conductor 
can result in a risk of electric shock. Check with a 
qualified electrician, or service representative or 
personnel, if you are in doubt as to whether the
appliance is properly grounded. DO NOT modify 
the plug on the power supply cord. If it will not 
fit the outlet, have a proper outlet installed by a 
qualified electrician. 
SAVE THESE INSTRUCTIONS
GROUNDING INSTRUCTIONS
For a permanently connected dryer: This 
dryer must be connected to a grounded metal, 
permanent wiring system, or an equipment-
grounding conductor must be run with the circuit 
conductors and connected to the equipment-
grounding terminal on the appliance.
Improper connection of the 
equipment-grounding conductor 
can result in a risk of electric shock. Check with a 
qualified electrician, or service representative or 
personnel, if you are in doubt as to whether the 
appliance is properly grounded.
SAVE THESE INSTRUCTIONS
WARNING
Fire Hazard
- Fire Hazard
WARNING
WARNING
Fire Hazard
- Fire Hazard
WARNING
WARNING
WARNING
CONNECTING AN ELECTRIC DRYER