Installation Instructions 24" Gas Built-In Oven JGRS06 Questions? Call 800.GE.CARES {800.432.2737} or Visit our Website at: www.GEAppliances.com BEFORE YOU BEGIN Read these instructions and warnings completely and carefully. IN THE COMMONWEALTH OF MASSACHUSETTS: * This product must be installed by a licensed plumber or gas fitter. * When using ball-type gas shut-off valves, they shall be the T-handle type. * A flexible gas connector, when used, must not exceed 3 feet.
Installation Instructions PREPARE TO INSTALL THE OVEN TOOLS YOU WILL NEED Drill with 1/8” Bit Safety Glasses CEDES — [rr] Adjustable Wrench Ruler or Straightedge Pipe Wrench Pencil EE 3/18" Hex Socket 127 Spirit Level Driver Phillips Screwdriver Hand or Saber Saw MATERIALS YOU MAY NEED shut-off valve Pipe joint sealant 1/2” pipe nipple FOR FLEXIBLE CONNECTION WHERE LOCAL CODES PERMIT: * Coated and approved flexible metal tubing {same 3/4" or 1/2" |.D.
Installation Instructions PREPARE THE OPENING 24” min. depth 24” min. width 22 3/16” width 38” height 3/8” min. on either side {See Fig. 2) it's best to use a template to make a straight cut. Place the template on a level base line, 22” 10 287 above the floor. This will place the oven cavity 368” or 42" above the floor. Cabinet space: Cutout: 24” 24” Ea MIN, MIN. j 22318” ~~ es 2 Runners on 117 Centers * SHOULD BE ADJUSTED TO SUIT BOTH STANDARD CABINETRY AND DESIRED OVEN WORKING HEIGHT. Oven 3/8" MIN.
Installation Instructions INSTALL THE OVEN [4] ELECTRICAL CONNECTIONS An adequate electrical supply and outlet must be used to operate the electrical parts of your oven. [A] The oven cord has a three-prong plug and must be used with a properly grounded three-hole outlet with a standard 120 Volt, 60 cycle AC household current. install the electrical outlet below the oven on the left side, in a location that is easily reached through the cabinet doors. (See Fig. 6).
Installation Instructions [5] GAS CONNECTIONS {cont.) Place the oven in the cutout. Level the oven: 1. Place a spirit level on one of the oven racks. 2. If the oven is not level, adjust the leg levelers. With the oven in place, remove the regulator cover by carefully grasping the left side and pull until the spring clip is released. The pressure regulator inlet is accessible through the opening in the main back. Remove regulator cover. Through this opening connect: 1.
Installation Instructions INSTALL THE OVEN (CONT) CHECK THE BURNER FLAMES FOR NATURAL GAS The oven is factory-adjusted for use with Natural Gas in most areas. But, since the gas in some areas may vary, you should check all adjustments described below. If you are to use LP. Gas, see LP. Adjustments at the back of this guide. NOTE: Bake and broil flame must be checked with the door closed to properly check flame characteristics. To properly check the burner, the oven bottom and oven baffle must be removed.
Installation Instructions MAKE THE L.P. GAS CONVERSION A WARNING: you are using L.P. {bottled} gas, all the adjustments described below must be made before you make any burner adjustments or use the oven. A WARNING: This conversion must be performed by a qualified installer or gas supplier in accordance with the manufacturer's instructions and all codes and requirements of the authority having jurisdiction. Failure to follow instructions could result in serious injury or property damage.
Installation Instructions MAKE THE L.P. GAS CONVERSION (CONT) [5] ADJUST AIR SHUTTER NOTE: The oven burner flame must be checked with the door closed to properly check flame characteristics. Turn on bake or broil. As you watch the flame with the oven door closed, check the following through the oven door window: [A] Burner flames should nat flutter or blow away from the burner. They should be blue in color with no trace of yellow. The inner cone of the flame should be approximately 1/2” to 3/4” long.
Horno A Gas Empotrado de 24” JGRS06 Instrucciones de Instalación Preguntas? Llame al 1.800.GE.CARES (800.432.2737) o bien visite nuestra pagina Web: www.GEAppliances.com ANTES DE EMPEZAR: Lea estas instrucciones y las advertencias completa y cuidadosamente, EN LA MANCOMUNIDAD DE MASSACHUSETTS: * Este producto debe ser instalado por un plomero licenciado 0 por un técnico de gas. * Cuando se encuentre usando válvulas de descorazone de gas tipo bola, deben ser del tipo T.
Instrucciones de Instalación PREPARACIÓN DE LA ABERTURA Espacio del gabinete: 24” min. de profundidad 24” min, de anchura 22 3/16” de anchura 38" de altura 3/8” min. en ambos lados {Vea Fig. 2} Es buena idea usar un modelo para hacer un corte derecho. Coligue el modelo sobre una linea base nivelada, 227 a 28” del piso. Esto colocara la cavidad del horno del piso. Abertura: 24” 24” Ea MIN, MIN.
Instrucciones de Instalación INSTALACIÓN DEL HORNO [4] CONEXIONES ELÉCTRICAS Un abastecimiento vy receptáculo eléctrico adecuado debe ser usado para operar las partes eléctricas de su harbo, [A El cordón del horno tiene un enchufe de tres patas y debe ser usado con un receptáculo de tres hoyos que haga tierra adecuadamente con corriente alterna normal de casa de 120 Voltios, 60 Ciclos.
Instrucciones de Instalación [5] CONEXIONES DEL GAS {con} Mm Claque el horno en el corte. Nivele el horno: 1. Coligue el nivel de espíritu sobre una de las parrillas del horno. 2. Si el horno no esta nivelado, ajuste los niveladores de las patas. Con el horno en su lugar, saque la cubierta de regulador tornando cuidadosamente el lado izquierdo y tirando hasta que el gancho se suelte. La entrada de regulador de presión es accesible a través de la abertura en la espalda principal.
Instrucciones de Instalación INSTALACIÓN DEL HORNO (CON. COMO REVISAR LAS LLAMAS DE LOS QUEMADORES A GAS NATURAL El horno viene ajustado de fabrica para ser usado con gas natural en la mayoritaria de las reas. Pero, como el pas en algunas áreas varia, usted debe revisar todos los ajustes que se describen mas abajo. Si usted va a usar gas LP, mire los Ajustes para Gas LP. en la parte final de esta guía.
Instrucciones de Instalación COMO HACER LA CONVERSIÓN PARA GAS L.P. A ADVERTENCIA: si usted va a usar gas LP {embotellador, todos fos ajustes descritos mas abajo deben hacer antes de hacer cualquier ajuste a los quemadores o usar el horno. A ADVERTENCIA: Esta conversión debe ser hecha por un instalador competente 0 por el abastecedor de gas de acuerdo con las instrucciones del fabricante y todos los códigos y requerimientos de las autoridades que tienen jurisdicción.
Instrucciones de Instalación COMO HACER LA CONVERSIÓN PARA GAS L.P. (CON) [5] AJUSTE EL OBTURADOR DE AIRE NOTA: Las llamas para hornear y asar se deberían revisar con la puerta cerrada para revisar correctamente las características de la lama. Encienda el quemador para hornear y para asar, Mientras mira la llama con la puerta cerrada, revise io siguiente a través de la ventana de la puerta: [A] tas llamas del quemador no deberían pestañear o soplar en dirección opuesta al quemador.