Installation guide

Installation Instructions
Electrical Connections
Turn off the circuit breaker or remove
fuses to the oven branch circuit.
With the oven in front of the cabinet
opening on a table or platform,
connect the flexible conduit to the
electrical junction box as shown
below. You will need to purchase a
strain relief clamp to complete the
connection of the conduit to the
junction box.
STRAIN RELIEF CLAMP
( NOT iNCLUDED }
MUST BE USED
New Construction and Four-
Conductor Branch Circuit
Connection
When installing in a new construction, or
When installing oven in a mobile home, or
When local codes do not permit grounding
through neutral:
a. Cut the neutral
(White) lead from
the crimp. Re-strip
the neutral (white)
lead to expose the
proper length of
conductor.
b.Attach the appliance
grounding lead (green or
bare copper)in accordance
with local codes. If the
residence grounding
conductor is aluminum, see
WARNING note on the
following page.
_, Ground
Wires
Junction
Box Cover
c. Connect the oven neutral (white) lead to
the branch circuit neutral (white or gray) in
accordance with local codes.
d. Connect the oven red lead to the branch
circuit red lead and the oven black lead to
the branch circuit black lead in accordance
with local codes. If the residence red,
black or white leads are aluminum
conductors, see" WARNING" note on the
following page.
e. Install the Junction Box Cover.
OR
6 (Continued on following page)