Installation guide

Installation Instructions
Electrical Connections cont
Three-Conductor Branch Circuit Connection
When connecting to a 3-conductor branch
circuit, if local codes permit:
a. Connect the bare oven ground conductor
with the crimped neutral (white) lead to the
branch circuit neutral (white or gray in
color).
b. The oven red lead to the branch circuit red
lead.
c. The oven black lead to the branch circuit
black lead in accordance with local codes.
d. Install Junction Box Cover.
Junction Box
Cover
NOTE TO ELECTRICIAN: The 3 power leads
supplied with this appliance are UL recognized
for connection to larger gauge household wiring.
The insulation of these 3 leads is rated at
temperatures much higher than the temperature
rating of household wiring. The current carrying
capacity of the conductor is governed by the
temperature rating of the insulation around the
wire, rather than the wire gauge alone.
WARNING: Improper connection of
aluminum house wiring to copper leads
can result in an electrical hazard or fire.
Use only connectors designed for joining
copper to aluminum and follow the
manufacturer's recommended procedure
closely.
i
Do not shorten this flexible conduit. The
conduit strain relief clamp must be
securely attached to the junction box and
the flexible conduit must be securely
attached to the clamp. If the flexible
conduit will not fit within the clamp, do
not install the oven until a clamp of the
proper size is obtained.