Installation Instructions

2 C
CUTOUT FOR DOUBLE OVENS (2 THERMAL OVENS)
NOTE: If the cabinet does not have a front frame and the sides are less than ¾” (1.9 cm) thick,
shim both sides equally to establish the cutout width.
2 D
CUTOUT FOR COMBINATION OVENS
(WITH UPPER MICROWAVE OVEN)
NOTE: If the cabinet does not have a front frame and the sides are less than ¾” (1.9 cm) thick,
shim both sides equally to establish the cutout width.
2 E
SECURING UPPER MICROWAVE/ADVANTIUM OVEN
TO CABINET
For double oven with microwave or Advantium upper ovens. Secure a wooden cleat to side of
cabinet so that the upper oven can be secured to the cleat with provided screws
27” Cabinet requirements
No shims (or cleats) required when cabinet is in
minimum width condition.
If cabinet is at maximum width condition, add wood
shims to bring cabinet to minimum condition.
30” Cabinet requirements
No shims (or cleats) required when cabinet is in
minimum width condition.
If cabinet is at maximum width condition, fix the wood
cleats as shown in illustration.
Dim. Description 27” Double Oven
30” Double Oven with
Pedestal
30” Double Oven
without Pedestal
A Cabinet Width 27” (68.6 cm) 30” (76.2 cm) 30” (76.2 cm)
B Cutout Width 25” (63.5 cm) min.
25
1
4” (64.1 cm) max.
28
1
2” (72.4 cm) min.
28
5
8” (72.7 cm) max.
28
1
2” (72.4 cm) min.
28
5
8” (72.7 cm) max.
C Cutout Height
49
11
16” (126.2 cm) min.
50
1
8” (127.3 cm) max.
51
13
16” (131.6 cm) min.
51
15
16” (131.9 cm) max.
50 ¼” (127.64cm)
D Clearance from
cutout - side
edges*
1” (2.5 cm)
11
16” (1.75 cm)
11
16” (1.75 cm)
E
Clearance to
Adjacent Corners,
Drawers, Walls, etc.,
When Door Is Open
23” (50.8 cm) min. 23” (53.3 cm) min. 23” (53.3 cm) min.
F Clearance from
cutout - top*
1” (2.5 cm) min. 1” (2.5 cm) min.
(1
1
4” (3.2 cm) for
PT9550, ZET2S and
ZET2P)
1” (2.5 cm) min.
(1
1
4” (3.2 cm) for
PT9550, ZET2S and
ZET2P)
G Clearance from
cutout - bottom*
1” (2.5 cm) min. 1
1
4” (3.2 cm) 1
1
4” (3.2 cm)
H Junction Box
Location
8
3
4” (22.2 cm) max.
right side only
9
1
2” (24.1 cm) max.
right side only
9
1
2” (24.1 cm) max.
right side only
J Height to Bottom
of Junction Box
44” (111.8 cm) 47” (119.4 cm) 47” (119.4 cm)
K Recommended
Cutout Location
from Floor
13
1
4” (33.7 cm) 12” (30.5 cm) 12” (30.5 cm)
Dim. Description
27” Oven
with Microwave
30” Oven
with Microwave
A Cabinet Width 27” (68.6 cm) 30” (76.2 cm)
B Cutout Width 25” (63.5 cm) min.
25
1
4” (64.1 cm) max.
28
1
2” (72.4 cm) min.
28
5
8” (72.7 cm) max.
C Cutout Height
41
1
8” (104.5 cm) min.
41
1
4” (104.8 cm) max.
42
3
16” (107.2 cm) min.
42
1
4” (107.3 cm) max.
D Clearance from cutout -
side edges*
1” (2.5 cm)
11
16” (1.75 cm)
E
Clearance to Adjacent Corners,
Drawers, Walls, etc., When Door
Is Open
23” (58.4 cm) min. 23” (58.4 cm)
F Clearance from cutout - top*
1” (2.5 cm) min. 1” (2.5 cm) min.
G Clearance from cutout -
bottom*
1” (2.5 cm) min. 1
1
4” (3.2 cm)
H Junction Box Location
8
3
4” (22.2 cm) max.
right side only
9
1
2” (24.1 cm) max.
right side only
2 A
CUTOUT FOR SINGLE OVENS IN WALL CABINET
NOTE: If the cabinet does not have a front frame and the sides are less than ¾” (1.9 cm) thick,
shim both sides equally to establish the cutout width.
BEFORE YOU BEGIN
Read these instructions completely and
carefully.
IMPORTANT Save these
instructions for local inspector’s use.
IMPORTANT Observe all
governing codes and ordinances.
Note to Installer – Be sure to leave these
instructions with Consumer.
Note to Consumer – Keep these
instructions for future reference.
Skill level – Installation of this appliance
requires a qualified installer or electrician.
Proper installation is the responsibility
of the installer.
Product failure due to improper installation
is not covered under Warranty.
Product is for indoor use only.
Installation Instructions
27” & 30 Electric Built-In Wall Ovens
FOR YOUR SAFETY:
WARNING
Before beginning the installation, switch power off at the service panel and lock
the service disconnecting means to prevent power from being switched on accidentally. When the
service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a
tag, to the service panel.
Be sure the oven is securely installed in a cabinet that is firmly attached to the house structure. Weight
on the oven door could cause the oven to tip and result in injury. Never allow anyone to climb, sit,
stand or hang on the oven door.
Make sure the wall coverings, counters and cabinets around the oven can withstand the heat (up to
200°F [93.3°C]) generated by the oven.
MATERIALS YOU MAY NEED
Junction Box
Wire Nuts
Strain Relief Clamp for 1/2” Conduit
36” (91 cm) of String
TOOLS YOU MAY NEED
1/8” Drill Bit and Electric or Hand Drill
T20 Screwdriver
Phillips Screwdriver
Wire Strippers
7/16” Nut Driver (combination ovens)
1/4” Nut Driver (30” combination ovens)
1
REMOVE PACKAGING MATERIALS
Failure to remove packaging materials could result in damage to the appliance. Remove all
packing parts from oven, racks and heating elements. Remove protective film and labels on
the outer door and control panel. Also, remove plastic on trims and panel, all tape around the
oven and any shipping screws securing the oven to the base pad. Open oven door and remove
literature pack and oven racks. Remove the bottom trim from the top of the oven. It will be
installed at the end of the installation process. The trim is wrapped separately and taped to the top
of the unit. Remove pedestal rails from separate box and set aside (30” Double Wall Ovens Only).
2
PREPARE THE OPENING
NOTE: If the cabinet does not have a solid
bottom, two braces or runners must be
installed to support the weight of the oven.
For single ovens, the runners and braces
must support 220 lbs (99 kg). For double and
combination ovens, the runners and braces
must support 400 lbs. (181 kg).
NOTE: If marks, blemishes or the cutout
opening are visible above the installed oven,
it may be necessary to add wood shims
under the runners until the marks or opening
are covered.
NOTE: If the cabinet does not have a front
frame and the sides are less than ¾” (1.9 cm)
thick, shim both sides equally to establish the
cutout width.
ATTENTION INSTALLER: All electric wall ovens must be hard-wired (direct-wired)
into an approved junction box. A plug and receptacle is NOT permitted on these products.
These ovens
are not
approved for
installations that
stack one single
wall oven above
another single
wall oven.
Cutout –
observe all
dimensions and
requirements.
Cutout –
observe all
dimensions and
requirements.
2” (5.1 cm) Min.
30.5” (77.5 cm)
30” models
27” (68.58 cm)
27” models
Center Line Center Line
Side-by-Side Installations
Install two ovens in separate cutouts.
2 B
CUTOUT FOR SINGLE OVENS – UNDER COUNTER
NOTE: These ovens are only approved to be installed under the specific models as labeled on
the unit.
NOTE: One cooktop may be centered over either
oven in the side-by-side installation.
Cutout – observe
all dimensions and
requirements.
2” (5.1 cm) Min.
30.5” (77.5 cm) 30” models
27” (68.58 cm) 27” models
Center Line Center Line
Side-by-Side Installations
Install two ovens in separate cutouts.
Cooktop
Cutout – observe
all dimensions and
requirements.
2 F
CUTOUT FOR INSTALLATION OVER A
WARMING DRAWER
NOTE: Install the oven only with specific models listed on the label located on top of the oven.
NOTE: Additional clearances between cutouts may be required. Check to be sure the oven
supports above the Warming Drawer location do not obstruct the required interior depth and height.
When installing a Warming Drawer below a single, double, or combination oven, a separate
120V, 60 HZ, properly grounded receptacle must be installed. Refer to installation instructions
packed with the Warming Drawer for specific installation requirements.
Anti-Tip Block Against
Rear Wall Per Warming
Drawer Requirement
2" (5.1 cm)
Min.
Per Warming
Drawer
Requirement
Continue to Section 3 for Double Wall Oven with Pedestal. Otherwise, continue to Section 4.
DESIGN INFORMATION
SINGLE OVEN INSTALLATIONS
The single oven may be installed in a cabinet alone or above a warming drawer. The single oven
may also be installed side by side, below a countertop, or below specified cooktops. See the label
on top of the oven for approved models.
DOUBLE AND COMBINATION OVEN INSTALLATIONS
A double or combination oven may be installed in a cabinet alone or above a warming drawer.
See the label on top of the oven for approved models.
IMPORTANT: Always refer to individual installation instructions packed with each product for
specific requirements.
Continue to Section 3.
Continue to Section 2E.
H
B
F
G
C
D
A
E
Junction
Box
Location
(junction
box may
be located
in adjacent
cabinet)
22” (55.9
cm) Min.
to Bottom
of Junction
Box
Cutout Depth
23-1/2”
(59.7 cm) Min.
Recommended
Cutout Location
from Floor
32-1/2” (82.6 cm)
Opening
Between Inside
Walls Must be
at Least 28-1/2”
(72.4 cm) Wide
H
B
C
K
F
G
D
A
J
E
Junction
Box
Location
(junction
box may
be located
in adjacent
cabinet)
Cutout Depth
23-1/2”
(59.7 cm) Min.
NOTE: Allow
1/4” (0.64 cm)
clearances from
side edges of
oven door.
3 A
DETERMINING WHEN TO USE THE PEDESTAL
(30” DOUBLE OVENS ONLY)
WHEN TO USE THE PEDESTAL
When replacing an older GE Appliances 30” double wall oven with a new GE Appliances model.
Cutout height = 51-13/16” to 51-15/16”. This is our traditional cutout height.
WHEN NOT TO USE THE PEDESTAL
When replacing a 30” double wall oven from another manufacturer (ie. Whirlpool) with a new
GE Appliances 30” double wall oven. Cutout height = 50-1/4”. You will need to verify that the
existing cutout matches the 50-1/4” dimension.
If the new GE Appliances 30” double wall oven is being installed into new construction (ie. not a
replacement), then the recommended installation is to use the Pedestal.
3 B
PEDESTAL RAIL INSTALLATION
(30” DOUBLE OVENS ONLY)
A. Position the pedestal rails with the top cutout toward the front of the opening and the flanges
on the bottom, pointing toward the center. Locate each rail on the floor or cabinet runner,
slightly inward from the side of the cabinet. Make sure the front of each rail is not protruding
beyond the front of the cabinet opening.
B. Drill pilot holes and attach rails to runner or bottom of cabinet with provided hardware.
31-11161 04-18 GEA
Continue to Section 4.
Dimension Dimension Description 27” Single Oven 30” Single Oven
A Cabinet Width 25” (63.5 cm) min.
25
1
4” (64.1 cm) max.
28
1
2” (72.4 cm) min.
28
5
8” (72.7 cm) max.
B Cutout Height 27
5
8” (70.2 cm) min.
28
1
8” (71.4 cm) max.
27
1
4” (69.2 cm) min.
27
5
16” (69.4 cm) max.
C Clearance from cutout - top* 1” (2.5 cm) 1” (2.5 cm)
(1
1
4” (3.2 cm) for
PT9050
ZET1S and ZET1P)
D Clearance from cutout - bottom* 1” (2.5 cm) 1
1
4” (3.2 cm)
E Clearance from cutout - side edges* 1” (2.5 cm)
11
16” (1.75 cm)
F Junction Box Location 8
3
4” (22.2 cm) max.
right side only
9
1
2” (24.1 cm) max.
right side only
* Refers to minimum clearance required for wall oven installation and does not reflect actual product dimensions.
Dimension Dimension Description 27” Single Oven 30” Single Oven
A Cabinet Width 27” (68.6 cm) 30” (76.2 cm)
B Cutout Width 25” (63.5 cm) min.
25
1
4” (64.1 cm) max.
28
1
2” (72.4 cm) min.
28
5
8” (72.7 cm) max.
C Cutout Height 27
5
8” (70.2 cm) min.
28
1
8” (71.4 cm) max.
27
1
4” (69.2 cm) min.
27
5
16” (69.4 cm) max.
D Clearance from cutout -
side edges*
1” (2.5 cm)
11
16” (1.75 cm)
E Clearance to Adjacent
Corners, Drawers, Walls,
etc., When Door Is Open
23” (50.8 cm) min. 23” (53.3 cm) min.
F Clearance from cutout -
top*
1” (2.5 cm) min. 1” (2.5 cm) min.
(1
1
4” (3.2 cm) for PT9050,
ZET1S and ZET1P)
G Clearance from cutout -
bottom*
1” (2.5 cm) min. 1
1
4” (3.2 cm)
H Junction Box Location 8
3
4” (22.2 cm) max.
right side only
9
1
2” (24.1 cm) max.
right side only
* Refers to minimum clearance required for wall oven installation and does not reflect actual product dimensions.
IMPORTANT: Maintain
a minimum distance
of 31-1/4” from the
top surface of the
countertop to the
wall oven platform to
ensure that the cooktop
and wall oven do not
interfere with each other
(see picture).
* Refers to minimum clearance required for wall oven installation and does not reflect actual product dimensions.
* Refers to minimum clearance required for wall oven installation and does not reflect actual product dimensions.
Flanges toward
center of cutout
Top cutout
toward front
Attachment
screws
31-1/4” min.
(79.4 cm)
SIDE VIEW
Cooktop
Wall Oven
2-1/2” min. (6.4cm)
Questions? Call us at 1.800.432.2737 or visit GEAppliances.com.
In Canada, call 1.800.561.3344 or visit GEAppliances.ca.
Suitable
Bracing
to Support
Runners
2" x 4" (5 cm x 10 cm)
or Equivalent Runners Level
with Bottom of Cutout
and Flush with Sides of Cutout
C
L
6.375”
27.5”
1.5”
3.0”
Cleat locations on 30” cabinet
with maximum cutout condition
Wood Cleats

Summary of content (4 pages)